Bellevue City of water quality

Updated 2026-10-22 · Washington · Affiliate disclosure

We read 10 results from Bellevue City of’s 2025 water quality report. No results over a legal limit; 2 above a health goal or guideline.

Serves about 317,330 people · Water system ID WA5305575 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Arsenicaverage · range 0.3 to 0.6 · Cedar, highest of 2 sources · 2025 report, page 60.5 ppb0.004 ppb10 ppbAbove the health goal125x the health goal
Lead90th percentile of 52 homes tested, 0 over the action level · sampled 2023 · Customer taps (52 homes) · 2025 report, page 73.7 ppb0.2 ppb15 ppb (action level)Above the health goal19x the health goal
Bariumaverage · range 0.0013 to 0.0022 · printed as 1.7 ppb · Cedar, highest of 2 sources · 2025 report, page 60.0017 ppm2 ppm2 ppmBelow the health goal
Chlorineaverage · range 0.1 to 1.79 · Distribution system · 2025 report, page 60.88 ppmNone set4 ppmBelow the legal limit
Copper90th percentile of 52 homes tested, 0 over the action level · sampled 2023 · Customer taps (52 homes) · 2025 report, page 70.11 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)system-wide average · range 14.2 to 37.1 · Distribution system · 2025 report, page 627 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)system-wide average · range 21 to 43.2 · Distribution system · 2025 report, page 631 ppbNone set80 ppbBelow the legal limit
Fluorideaverage · range 0.5 to 0.75 · Cedar, highest of 2 sources · 2025 report, page 60.7 ppm1 ppm4 ppmBelow the health goal
Turbidity (cloudiness)highest measured · range 0.02 to 0.28 · Tolt · 2025 report, page 60.28 NTUNone set1 NTUBelow the legal limit
Total organic carbonaverage · range 1.1 to 1.5 · Tolt (raw water), highest of 2 sources · 2025 report, page 61.3 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 1 number we weren’t sure about is held back until a person checks.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Arsenic

Found: Arsenic

What removes it: Reverse osmosis.

See filters that remove it

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

More districts: Washington water quality · All states · Something look wrong? Tell us