Alderwood Water District water quality

Updated 2026-10-22 · Washington · Affiliate disclosure

We read 13 results from Alderwood Water District’s 2025 water quality report. No results over a legal limit; 2 above a health goal or guideline.

Serves about 200,000 people · Water system ID WA5301300 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Arsenicaverage · range ND to 0.14 · Everett treatment plant · 2025 report, page 140.11 ppb0.004 ppb10 ppbAbove the health goal28x the health goal
Lead90th percentile of 108 homes tested, 0 over the action level · sampled 2024 · Customer taps (108 homes, regional group) · 2025 report, page 142 ppb0.2 ppb15 ppb (action level)Above the health goal10x the health goal
Chlorineaverage · range 0.2 to 1.4 · Distribution system · 2025 report, page 130.74 ppmNone set4 ppmBelow the legal limit
Copper90th percentile of 108 homes tested, 0 over the action level · sampled 2024 · Customer taps (108 homes, regional group) · 2025 report, page 140.09 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range 30 to 47.7 · Distribution system · 2025 report, page 1338.8 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 42.2 to 68 · Distribution system · 2025 report, page 1352.6 ppbNone set80 ppbBelow the legal limit
Fluorideaverage · range 0.2 to 0.7 · Distribution system · 2025 report, page 130.6 ppm1 ppm4 ppmBelow the health goal
Total coliform bacteriahighest month · Distribution system · 2025 report, page 13Not detected0 % positive5 % positiveNot detected
Turbidity (cloudiness)highest measured · Everett treatment plant · 2025 report, page 130.04 NTUNone set1 NTUBelow the legal limit
Bromodichloromethaneaverage · range 1.4 to 2.2 · Distribution system · 2025 report, page 141.8 ppbNone setNoneNo health limit
Chloroformaverage · range 29.4 to 66 · Distribution system · 2025 report, page 1441.8 ppbNone setNoneNo health limit
Hardnessaverage · range 0.6 to 0.92 · Everett distribution system · 2025 report, page 140.73 gpg (12.5 ppm)——Soft
Sodiumaverage · range 4.9 to 7.1 · Everett treatment plant · 2025 report, page 146 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Arsenic

Found: Arsenic

What removes it: Reverse osmosis.

See filters that remove it

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

More districts: Washington water quality · All states · Something look wrong? Tell us