New England Kurn Hattin Homes water quality

Updated 2026-10-22 · Vermont · Affiliate disclosure

We read 21 results from New England Kurn Hattin Homes’s 2025 water quality report. No results over a legal limit; 8 above a health goal or guideline.

Serves about 200 people · Water system ID VT0005452 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Arsenichighest measured · range 3.4 to 5.6 · 2025 report5.6 ppb0.004 ppb10 ppbAbove the health goal1,400x the health goal
Copper90th percentile of homes tested, 0 over the action level · Customer taps · 2025 report0.61 ppm0.3 ppm1.3 ppm (action level)Above the health goal2x the health goal
Gross alpha (radioactivity)highest measured · range 1.4 to 1.4 · highest of 2 sources · 2025 report1.4 pCi/L0 pCi/L15 pCi/LAbove the health goalThe health goal is zero
Lead90th percentile of homes tested, 0 over the action level · Customer taps · 2025 report2 ppb0.2 ppb15 ppb (action level)Above the health goal10x the health goal
Manganesehighest measured · range ND to 0.25 · printed as 253 ppb · 2025 report0.25 ppm—0.05 ppm guidelineAbove the guideline5.1x the guideline (taste, odor or stains; not a health limit)
Radium (combined 226 + 228)highest measured · range 0.8 to 0.8 · sampled 2022 · 2025 report0.8 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Radium-226highest measured · range 0.4 to 0.4 · sampled 2022 · 2025 report0.4 pCi/L0.05 pCi/L5 pCi/LAbove the health goal8x the health goal
Radium-228highest measured · range 0.4 to 0.4 · sampled 2022 · 2025 report0.4 pCi/L0.02 pCi/L5 pCi/LAbove the health goal21x the health goal
Bariumhighest measured · range 0.02 to 0.02 · 2025 report0.02 ppm2 ppm2 ppmBelow the health goal
Chlorinehighest running annual average · range 0.2 to 1.3 · Distribution system · 2025 report0.69 ppmNone set4 ppmBelow the legal limit
Chromium (total)highest measured · range 2 to 2 · 2025 report2 ppbNone set100 ppbBelow the legal limit
Disinfection byproducts (HAA5)highest running annual average · range 2 to 2 · sampled 2023 · MAUDE PARENT COTTAGE, highest of 2 sources · 2025 report2 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 13 to 13 · sampled 2023 · MAUDE PARENT COTTAGE, highest of 2 sources · 2025 report13 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.98 to 0.98 · 2025 report0.98 ppm1 ppm4 ppmBelow the health goal
Ironhighest measured · range 0.22 to 0.22 · 2025 report0.22 ppm—0.3 ppm guidelineWithin the guideline
Nitrate (as N)highest measured · range 1.4 to 1.4 · 2025 report1.4 ppm10 ppm10 ppmBelow the health goal
PFHxS (a PFAS)single sample · sampled 2023 · Entry point · 2025 reportNot detectedNone set20 ppt (Vermont) now; 10 ppt from 2029Not detected
PFNA (a PFAS)single sample · sampled 2023 · Entry point · 2025 reportNot detectedNone set20 ppt (Vermont) now; 10 ppt from 2029Not detected
PFOA (a PFAS)single sample · sampled 2023 · Entry point · 2025 reportNot detected0.007 ppt20 ppt (Vermont) now; 4 ppt from 2029Not detected
PFOS (a PFAS)single sample · sampled 2023 · Entry point · 2025 reportNot detected1 ppt20 ppt (Vermont) now; 4 ppt from 2029Not detected
PFHpA (a PFAS)single sample · sampled 2023 · Entry point · 2025 reportNot detectedNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Arsenic

Found: Arsenic

What removes it: Reverse osmosis.

See filters that remove it

Lead

Found: Copper, Lead

What removes it: Reverse osmosis or Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Radium and uranium

Found: Gross alpha (radioactivity), Radium (combined 226 + 228), Radium-226, Radium-228

What removes it: Reverse osmosis.

See filters that remove it

Sediment or cloudy water

Found: Manganese

What removes it: Oxidation filter.

See filters that remove it

More districts: Vermont water quality · All states · Something look wrong? Tell us