Chesterfield Co Central Water System water quality

Updated 2026-10-22 · Virginia · Affiliate disclosure

We read 20 results from Chesterfield Co Central Water System’s 2025 water quality report. No results over a legal limit; 6 above a health goal or guideline.

Serves about 383,115 people · Water system ID VA4041845 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Chloritehighest measured · range ND to 0.39 · ARWA plant · 2025 report, page 40.39 ppm0.05 ppm1 ppmAbove the health goal7.8x the health goal
Fluoridehighest measured · range 0.02 to 3.86 · Richmond plant, highest of 3 sources · 2025 report, page 43.86 ppm1 ppm4 ppmAbove the 2 ppm secondary standard1.9x the 2 ppm secondary standard (EPA's level to prevent tooth discoloration, also used as health guidance); below the 4 ppm legal limit
Gross alpha (radioactivity)as reported · Richmond plant · 2025 report, page 40.41 pCi/L0 pCi/L15 pCi/LAbove the health goalThe health goal is zero
Gross beta (radioactivity)as reported · Addison-Evans plant · 2025 report, page 42.3 pCi/L0 pCi/L50 pCi/LAbove the health goalThe health goal is zero
PFOA (a PFAS)highest measured · range 1.9 to 2.1 · Addison-Evans plant · 2025 report, page 32.1 ppt0.007 ppt4 ppt from 2029Above the health goal300x the health goal
Radium (combined 226 + 228)as reported · Richmond plant · 2025 report, page 41.02 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Bariumas reported · Addison-Evans plant, highest of 3 sources · 2025 report, page 40.04 ppm2 ppm2 ppmBelow the health goal
Chloraminehighest running annual average · range 0.1 to 4.2 · County distribution system · 2025 report, page 42.34 ppmNone set4 ppmBelow the legal limit
Copper90th percentile of 50 homes tested, 0 over the action level · Customer taps · 2025 report, page 40.11 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range 7 to 40 · Richmond area, highest of 3 sources · 2025 report, page 431 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 14 to 49 · Addison-Evans area, highest of 3 sources · 2025 report, page 436.7 ppbNone set80 ppbBelow the legal limit
Lead90th percentile of 50 homes tested, 0 over the action level · Customer taps · 2025 report, page 4Not detected0.2 ppb15 ppb (action level)Not detected
Nitrate (as N)as reported · Richmond plant, highest of 2 sources · 2025 report, page 40.25 ppm10 ppm10 ppmBelow the health goal
Sulfateas reported · Addison-Evans plant · 2025 report, page 540.6 ppm—250 ppm guidelineWithin the guideline
Turbidity (cloudiness)highest measured · range 0.01 to 0.44 · Richmond plant, highest of 3 sources · 2025 report, page 40.44 NTUNone set1 NTUBelow the legal limit
PFBA (a PFAS)highest measured · range 3 to 4.9 · Addison-Evans plant · 2025 report, page 34.9 pptNone setNoneNo health limit
PFBS (a PFAS)highest measured · range 2.1 to 2.3 · Addison-Evans plant · 2025 report, page 32.3 pptNone setNoneNo health limit
PFHxA (a PFAS)highest measured · range 1.9 to 2 · Addison-Evans plant · 2025 report, page 32 pptNone setNoneNo health limit
PFPeA (a PFAS)highest measured · range 1.9 to 2.1 · Addison-Evans plant · 2025 report, page 32.1 pptNone setNoneNo health limit
Sodiumas reported · ARWA plant · 2025 report, page 519.4 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Disinfection byproducts

Found: Chlorite

What removes it: Carbon block.

See filters that remove it

Fluoride

Found: Fluoride

What removes it: Reverse osmosis.

See filters that remove itDo water filters remove fluoride?

Radium and uranium

Found: Gross alpha (radioactivity), Gross beta (radioactivity), Radium (combined 226 + 228)

What removes it: Reverse osmosis.

See filters that remove it

PFAS ("forever chemicals")

Found: PFOA (a PFAS)

What removes it: Reverse osmosis.

See filters that remove itWhat water filter removes PFAS?

More districts: Virginia water quality · All states · Something look wrong? Tell us