We read 17 results from West Jordan City Water System’s 2025 water quality report. No results over a legal limit; 5 above a health goal or guideline.

Serves about 117,025 people · Water system ID UTAH18020 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Arsenicaverage · Sources (average) · 2025 report1.7 ppb0.004 ppb10 ppbAbove the health goal425x the health goal
Chloriteaverage · range 0.08 to 0.48 · Distribution system · 2025 report0.26 ppm0.05 ppm1 ppmAbove the health goal5.2x the health goal
Gross alpha (radioactivity)average · range 0.5 to 8.2 · Sources (average) · 2025 report3.1 pCi/L0 pCi/L15 pCi/LAbove the health goalThe health goal is zero
Lead90th percentile of homes tested, 0 over the action level · Customer taps · 2025 report2.23 ppb0.2 ppb15 ppb (action level)Above the health goal11x the health goal
Uraniumaverage · Sources (average) · 2025 report3 ppb0.6 ppb30 ppbAbove the health goal5x the health goal
Bariumaverage · printed as 59.3 ug/L · Sources (average) · 2025 report0.06 ppm2 ppm2 ppmBelow the health goal
Chlorineaverage · range 0.14 to 0.89 · Distribution system · 2025 report0.56 ppmNone set4 ppmBelow the legal limit
Copper90th percentile of homes tested, 0 over the action level · printed as 252 ppb · Customer taps · 2025 report0.25 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range 8.19 to 27.3 · Distribution system · 2025 report21.8 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 18.2 to 51.6 · Distribution system · 2025 report37.9 ppbNone set80 ppbBelow the legal limit
Fluorideaverage · Sources (average) · 2025 report0.14 ppm1 ppm4 ppmBelow the health goal
Nitrate (as N)average · Sources (average) · 2025 report1.44 ppm10 ppm10 ppmBelow the health goal
Seleniumaverage · Sources (average) · 2025 report0.7 ppb30 ppb50 ppbBelow the health goal
Total dissolved solidsaverage · Sources (average) · 2025 report281 ppm—500 ppm guidelineWithin the guideline
Turbidity (cloudiness)highest measured · range 0.01 to 0.15 · Surface water sources · 2025 report0.15 NTUNone set1 NTUBelow the legal limit
Hardnessaverage · range 0.94 to 35.2 · Sources (average) · 2025 report10.7 gpg (183 ppm)——Very hard
Sodiumaverage · range 8 to 77.9 · Sources (average) · 2025 report26.2 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in West Jordan City Water System’s water between Aug 2023 and Dec 2024. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • PFBS3.1 pptFound in 1 of 12 samples · highest resultNo federal limit in force for this one
  • Lithium50 ppbFound in 12 of 12 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Arsenic

Found: Arsenic

What removes it: Reverse osmosis.

See filters that remove it

Disinfection byproducts

Found: Chlorite

What removes it: Carbon block.

See filters that remove it

Radium and uranium

Found: Gross alpha (radioactivity), Uranium

What removes it: Reverse osmosis.

See filters that remove it

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?