Washington City water quality

Updated 2026-10-22 · Utah · Affiliate disclosure

We read 20 results from Washington City’s 2025 water quality report. No results over a legal limit; 6 above a health goal or guideline.

Water system ID UTAH27021 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Arsenichighest measured · range 1.3 to 3.8 · listed as a violation in the report · Sources · 2025 report, page 43.8 ppb0.004 ppb10 ppbAbove the health goal950x the health goal
Gross alpha (radioactivity)highest measured · listed as a violation in the report · Sources · 2025 report, page 53.77 pCi/L0 pCi/L15 pCi/LAbove the health goalThe health goal is zero
Lead90th percentile of homes tested, 0 over the action level · listed as a violation in the report · sampled 2024 · Customer taps · 2025 report, page 42.1 ppb0.2 ppb15 ppb (action level)Above the health goal11x the health goal
Radium (combined 226 + 228)highest measured · range 0.03 to 2.41 · listed as a violation in the report · Sources · 2025 report, page 52.41 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Total dissolved solidshighest measured · range 210 to 656 · listed as a violation in the report · Sources · 2025 report, page 5656 ppm—500 ppm guidelineAbove the guideline1.3x the guideline (taste, odor or stains; not a health limit)
Uraniumhighest measured · range 0.69 to 2.7 · listed as a violation in the report · Sources · 2025 report, page 52.7 ppb0.6 ppb30 ppbAbove the health goal4.5x the health goal
Antimonyhighest measured · listed as a violation in the report · Sources · 2025 report, page 40.6 ppb1 ppb6 ppbBelow the health goal
Bariumhighest measured · range 0.05 to 0.11 · listed as a violation in the report · printed as 111 ppb · Sources · 2025 report, page 40.11 ppm2 ppm2 ppmBelow the health goal
Chromium (total)highest measured · range ND to 2.2 · listed as a violation in the report · Sources · 2025 report, page 42.2 ppbNone set100 ppbBelow the legal limit
Copper90th percentile of homes tested, 0 over the action level · listed as a violation in the report · sampled 2024 · Customer taps · 2025 report, page 40.09 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Cyanidehighest measured · listed as a violation in the report · Sources · 2025 report, page 46.1 ppb150 ppb200 ppbBelow the health goal
Disinfection byproducts (HAA5)highest measured · range ND to 17.4 · listed as a violation in the report · Distribution system · 2025 report, page 517.4 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest measured · range 5 to 48 · listed as a violation in the report · Distribution system · 2025 report, page 548 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.03 to 0.25 · listed as a violation in the report · printed as 253 ppb · Sources · 2025 report, page 40.25 ppm1 ppm4 ppmBelow the health goal
Nitrate (as N)highest measured · listed as a violation in the report · Sources · 2025 report, page 41.9 ppm10 ppm10 ppmBelow the health goal
Seleniumhighest measured · range ND to 4.2 · listed as a violation in the report · Sources · 2025 report, page 54.2 ppb30 ppb50 ppbBelow the health goal
Sulfatehighest measured · range 32 to 198 · listed as a violation in the report · Sources · 2025 report, page 5198 ppm—250 ppm guidelineWithin the guideline
Turbidity (cloudiness)highest measured · listed as a violation in the report · Surface water plant · 2025 report, page 40.22 NTUNone set1 NTUBelow the legal limit
Nickelhighest measured · range ND to 9 · listed as a violation in the report · Sources · 2025 report, page 49 ppbNone setNoneNo health limit
Sodiumhighest measured · range 8 to 53.4 · listed as a violation in the report · Sources · 2025 report, page 553.4 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Washington City’s water between Oct 2023 and Jul 2024. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium29.1 ppbFound in 6 of 6 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Arsenic

Found: Arsenic

What removes it: Reverse osmosis.

See filters that remove it

Radium and uranium

Found: Gross alpha (radioactivity), Radium (combined 226 + 228), Uranium

What removes it: Reverse osmosis.

See filters that remove it

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Salty taste / high TDS

Found: Total dissolved solids

What removes it: Reverse osmosis.

See filters that remove it

More districts: Utah water quality · All states · Something look wrong? Tell us