Orem City Water System water quality

Updated 2026-10-22 · Utah · Affiliate disclosure

We read 13 results from Orem City Water System’s 2025 water quality report. No results over a legal limit; 3 above a health goal or guideline.

Serves about 98,129 people · Water system ID UTAH25020 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Arsenichighest measured · range ND to 1.9 · City of Orem · 2025 report, page 41.9 ppb0.004 ppb10 ppbAbove the health goal475x the health goal
Gross alpha (radioactivity)highest measured · sampled 2024 · City of Orem · 2025 report, page 44.1 pCi/L0 pCi/L15 pCi/LAbove the health goalThe health goal is zero
Radium-228highest measured · range 0.08 to 0.91 · sampled 2024 · City of Orem · 2025 report, page 40.91 pCi/L0.02 pCi/L5 pCi/LAbove the health goal48x the health goal
Bariumhighest measured · range 0.03 to 0.09 · City of Orem · 2025 report, page 40.09 ppm2 ppm2 ppmBelow the health goal
Chlorinehighest measured · range 0.05 to 1.3 · sampled 2024 · City of Orem · 2025 report, page 31.3 ppmNone set4 ppmBelow the legal limit
Disinfection byproducts (HAA5)highest measured · range ND to 32.6 · City of Orem · 2025 report, page 332.6 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest measured · range ND to 54.8 · City of Orem · 2025 report, page 354.8 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range ND to 0.21 · sampled 2024 · City of Orem · 2025 report, page 40.21 ppm1 ppm4 ppmBelow the health goal
Nitrate (as N)highest measured · range 0.36 to 1.83 · City of Orem · 2025 report, page 41.83 ppm10 ppm10 ppmBelow the health goal
Seleniumhighest measured · range ND to 4.2 · City of Orem · 2025 report, page 44.2 ppb30 ppb50 ppbBelow the health goal
Total coliform bacteriahighest month · City of Orem · 2025 report, page 3Not detected0 % positive5 % positiveNot detected
Turbidity (cloudiness)highest measured · range ND to 0.32 · City of Orem · 2025 report, page 30.32 NTUNone set1 NTUBelow the legal limit
Lithiumhighest measured · range ND to 26.9 · City of Orem · 2025 report, page 526.9 ppbNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Orem City Water System’s water between Jan 2025 and Oct 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium26.9 ppbFound in 12 of 16 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Arsenic

Found: Arsenic

What removes it: Reverse osmosis.

See filters that remove it

Radium and uranium

Found: Gross alpha (radioactivity), Radium-228

What removes it: Reverse osmosis.

See filters that remove it

More districts: Utah water quality · All states · Something look wrong? Tell us