Lehi City water quality

Updated 2026-10-22 · Utah · Affiliate disclosure

We read 17 results from Lehi City’s 2025 water quality report. 1 result over a legal limit and 4 above a health goal or guideline.

Serves about 79,978 people · Water system ID UTAH25015 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Turbidity (cloudiness)highest measured · listed as a violation in the report · Groundwater wells, highest of 2 sources · 2025 report, page 54.2 NTUNone set1 NTUOver the legal limit4.2x the legal limit
Arsenichighest measured · range 1.8 to 3 · listed as a violation in the report · Lehi sources · 2025 report, page 63 ppb0.004 ppb10 ppbAbove the health goal750x the health goal
Gross alpha (radioactivity)highest measured · range 0.44 to 9.85 · listed as a violation in the report · Lehi sources · 2025 report, page 79.85 pCi/L0 pCi/L15 pCi/LAbove the health goalThe health goal is zero
Lead90th percentile of homes tested, 0 over the action level · listed as a violation in the report · sampled 2024 · Customer taps · 2025 report, page 63 ppb0.2 ppb15 ppb (action level)Above the health goal15x the health goal
Radium (combined 226 + 228)highest measured · range ND to 4.7 · listed as a violation in the report · Lehi sources · 2025 report, page 74.7 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Antimonyhighest measured · range ND to 0.7 · listed as a violation in the report · Lehi sources · 2025 report, page 60.7 ppb1 ppb6 ppbBelow the health goal
Bariumhighest measured · range 0.06 to 0.24 · listed as a violation in the report · printed as 238 ppb · Lehi sources · 2025 report, page 60.24 ppm2 ppm2 ppmBelow the health goal
Chlorinehighest measured · range 0.2 to 0.8 · listed as a violation in the report · Distribution system · 2025 report, page 70.8 ppmNone set4 ppmBelow the legal limit
Cyanidehighest measured · range ND to 6 · listed as a violation in the report · Lehi sources · 2025 report, page 66 ppb150 ppb200 ppbBelow the health goal
Disinfection byproducts (HAA5)highest measured · range ND to 22 · listed as a violation in the report · Distribution system · 2025 report, page 722 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest measured · range ND to 25 · listed as a violation in the report · Distribution system · 2025 report, page 725 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.01 to 0.28 · listed as a violation in the report · printed as 282 ppb · Lehi sources · 2025 report, page 60.28 ppm1 ppm4 ppmBelow the health goal
Nitrate (as N)highest measured · listed as a violation in the report · Lehi sources · 2025 report, page 62 ppm10 ppm10 ppmBelow the health goal
Seleniumhighest measured · range ND to 7 · listed as a violation in the report · Lehi sources · 2025 report, page 67 ppb30 ppb50 ppbBelow the health goal
Sulfatehighest measured · range 4 to 40 · listed as a violation in the report · Lehi sources · 2025 report, page 640 ppm—250 ppm guidelineWithin the guideline
Total dissolved solidshighest measured · range 120 to 388 · listed as a violation in the report · Lehi sources · 2025 report, page 6388 ppm—500 ppm guidelineWithin the guideline
Sodiumhighest measured · range 5 to 45 · listed as a violation in the report · Lehi sources · 2025 report, page 645 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Lehi City’s water between Jan 2025 and Oct 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium21.4 ppbFound in 8 of 16 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Sediment or cloudy water

Found: Turbidity (cloudiness)

What removes it: Sediment filter.

See filters that remove it

Arsenic

Found: Arsenic

What removes it: Reverse osmosis.

See filters that remove it

Radium and uranium

Found: Gross alpha (radioactivity), Radium (combined 226 + 228)

What removes it: Reverse osmosis.

See filters that remove it

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

More districts: Utah water quality · All states · Something look wrong? Tell us