Walnut Creek SUD water quality

Updated 2026-10-22 · Texas · Affiliate disclosure

We read 14 results from Walnut Creek SUD’s 2025 water quality report. No results over a legal limit; 3 above a health goal or guideline.

Serves about 30,364 people · Water system ID TX1840008 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Arsenichighest measured · range 1.2 to 1.2 · Treated water · 2025 report, page 71.2 ppb0.004 ppb10 ppbAbove the health goal300x the health goal
Gross beta (radioactivity)highest measured · range 6.3 to 6.3 · sampled 2023 · Treated water · 2025 report, page 76.3 pCi/L0 pCi/L50 pCi/LAbove the health goalThe health goal is zero
Lead90th percentile of homes tested, 0 over the action level · sampled 2024 · Customer taps · 2025 report, page 51.2 ppb0.2 ppb15 ppb (action level)Above the health goal6x the health goal
Bariumhighest measured · range 0.08 to 0.08 · Treated water · 2025 report, page 70.08 ppm2 ppm2 ppmBelow the health goal
Chloramineaverage · range 0.2 to 4.4 · Distribution system · 2025 report, page 52.98 ppmNone set4 ppmBelow the legal limit
Copper90th percentile of homes tested, 0 over the action level · sampled 2024 · Customer taps · 2025 report, page 50.05 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Cyanidehighest measured · range 39.4 to 39.4 · Treated water · 2025 report, page 739.4 ppb150 ppb200 ppbBelow the health goal
DEHP (a phthalate)highest measured · range ND to 0.5 · Treated water · 2025 report, page 70.5 ppb12 ppb6 ppbBelow the health goal
Disinfection byproducts (HAA5)highest running annual average · range 34 to 34 · listed as a violation in the report · Distribution system · 2025 report, page 633 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 75.6 to 75.6 · listed as a violation in the report · Distribution system · 2025 report, page 663 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.16 to 0.16 · Treated water · 2025 report, page 70.16 ppm1 ppm4 ppmBelow the health goal
Nitrate (as N)highest measured · range 0.32 to 0.32 · Treated water · 2025 report, page 70.32 ppm10 ppm10 ppmBelow the health goal
Turbidity (cloudiness)highest measured · listed as a violation in the report · Walnut Creek SWTP · 2025 report, page 71 NTUNone set1 NTUBelow the legal limit
Dibromochloromethanehighest measured · range 6.09 to 17.4 · Treated water · 2025 report, page 717.4 ppbNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Arsenic

Found: Arsenic

What removes it: Reverse osmosis.

See filters that remove it

Radium and uranium

Found: Gross beta (radioactivity)

What removes it: Reverse osmosis.

See filters that remove it

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?