We read 22 results from Dallas Water Utility’s 2025 water quality report. No results over a legal limit; 4 above a health goal or guideline.

Serves about 1,356,479 people · Water system ID TX0570004 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Copper90th percentile of homes tested, 0 over the action level · sampled 2024 · Customer taps · 2025 report, page 50.39 ppm0.3 ppm1.3 ppm (action level)Above the health goal1.3x the health goal
Gross beta (radioactivity)average · range 5.3 to 6.2 · sampled 2023 · System-wide · 2025 report, page 45.7 pCi/L0 pCi/L50 pCi/LAbove the health goalThe health goal is zero
Lead90th percentile of homes tested, 0 over the action level · sampled 2024 · Customer taps · 2025 report, page 51.1 ppb0.2 ppb15 ppb (action level)Above the health goal5.5x the health goal
Total coliform bacteriahighest month · Distribution system · 2025 report, page 61.8 % positive0 % positive5 % positiveAbove the health goalThe health goal is zero
Aluminumaverage · range ND to 0.008 · printed as 5 ppb · System-wide · 2025 report, page 40.005 ppm—0.2 ppm guidelineWithin the guideline
Atrazineaverage · range 0.1 to 0.1 · System-wide · 2025 report, page 50.1 ppb0.15 ppb3 ppbBelow the health goal
Bariumaverage · range 0.04 to 0.04 · System-wide · 2025 report, page 40.04 ppm2 ppm2 ppmBelow the health goal
Bromateaverage · System-wide · 2025 report, page 5Not detected0.1 ppb10 ppbNot detected
Chloramineaverage · range 2.75 to 3.18 · Distribution system · 2025 report, page 52.97 ppmNone set4 ppmBelow the legal limit
Cyanideaverage · range ND to 76.8 · System-wide · 2025 report, page 445.2 ppb150 ppb200 ppbBelow the health goal
Disinfection byproducts (HAA5)highest running annual average · range 1.4 to 16.4 · Distribution system · 2025 report, page 515.1 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 6.5 to 21 · Distribution system · 2025 report, page 519.7 ppbNone set80 ppbBelow the legal limit
Fluorideaverage · range 0.55 to 0.69 · System-wide · 2025 report, page 40.63 ppm1 ppm4 ppmBelow the health goal
Manganeseaverage · range ND to 0.0068 · printed as 2.27 ppb · System-wide · 2025 report, page 40.0023 ppm—0.05 ppm guidelineWithin the guideline
Nitrate (as N)average · range 0.59 to 0.8 · System-wide · 2025 report, page 40.67 ppm10 ppm10 ppmBelow the health goal
Nitrite (as N)average · range ND to 0.02 · sampled 2022 · System-wide · 2025 report, page 40.006 ppm1 ppm1 ppmBelow the health goal
Simazineaverage · range ND to 0.08 · System-wide · 2025 report, page 50.03 ppb4 ppb4 ppbBelow the health goal
Turbidity (cloudiness)highest measured · Water treatment plants · 2025 report, page 60.16 NTUNone set1 NTUBelow the legal limit
Bromodichloromethaneaverage · range 3.42 to 5.97 · Distribution system · 2025 report, page 64.43 ppbNone setNoneNo health limit
Bromoformaverage · range ND to 1.95 · Distribution system · 2025 report, page 60.65 ppbNone setNoneNo health limit
Chloroformaverage · range 1.92 to 8.99 · Distribution system · 2025 report, page 64.57 ppbNone setNoneNo health limit
Dibromochloromethaneaverage · range 2.76 to 4.79 · Distribution system · 2025 report, page 63.5 ppbNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Dallas Water Utility’s water between Mar 2023 and Jan 2024. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • PFOA6.3 pptFound in 4 of 12 samples · highest resultAbove the federal limit that takes effect in 2029 (4 ppt)
  • PFOS5.1 pptFound in 2 of 12 samples · highest resultAbove the federal limit that takes effect in 2029 (4 ppt)
  • PFHxS3.8 pptFound in 3 of 12 samples · highest resultNo federal limit in force for this one
  • PFBS7.6 pptFound in 12 of 12 samples · highest resultNo federal limit in force for this one

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Lead

Found: Copper, Lead

What removes it: Reverse osmosis or Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Radium and uranium

Found: Gross beta (radioactivity)

What removes it: Reverse osmosis.

See filters that remove it

Bacteria and viruses

Found: Total coliform bacteria

What removes it: UV purification (and tell your utility).

See filters that remove itDo I need a UV water purifier?

PFAS ("forever chemicals")

Found: PFOA (EPA testing), PFOS (EPA testing)

What removes it: Reverse osmosis.

See filters that remove itWhat water filter removes PFAS?

More districts: Texas water quality · All states · Something look wrong? Tell us