We read 9 results from City of Tyler’s 2025 water quality report. No results over a legal limit; 1 above a health goal or guideline.
Serves about 105,047 people · Water system ID TX2120004 · Read the district’s 2025 report (opens in a new tab)
Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.
Results from the 2025 report
Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.
| Contaminant | Result | Health goal | Legal limit | What it means |
|---|---|---|---|---|
| Gross beta (radioactivity)highest measured · range ND to 4.9 · sampled 2023 · Treated water · 2025 report, page 4 | 4.9 pCi/L | 0 pCi/L | 50 pCi/L | Above the health goalThe health goal is zero |
| Bariumhighest measured · range 0.05 to 0.06 · Treated water · 2025 report, page 4 | 0.06 ppm | 2 ppm | 2 ppm | Below the health goal |
| Chloramineaverage · range 0.8 to 2.7 · Distribution system · 2025 report, page 4 | 1.96 ppm | None set | 4 ppm | Below the legal limit |
| Copper90th percentile of homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 4 | Not detected | 0.3 ppm | 1.3 ppm (action level) | Not detected |
| Fluoridehighest measured · range 0.04 to 0.05 · Treated water · 2025 report, page 4 | 0.05 ppm | 1 ppm | 4 ppm | Below the health goal |
| Lead90th percentile of homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 4 | Not detected | 0.2 ppb | 15 ppb (action level) | Not detected |
| Nitrate (as N)highest measured · range 0.36 to 0.45 · Treated water · 2025 report, page 4 | 0.45 ppm | 10 ppm | 10 ppm | Below the health goal |
| Turbidity (cloudiness)highest measured · Lake Palestine plant · 2025 report, page 5 | 0.3 NTU | None set | 1 NTU | Below the legal limit |
| Dibromochloromethanehighest measured · range 1.86 to 10.2 · Treated water · 2025 report, page 4 | 10.2 ppb | None set | None | No health limit |
Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 2 numbers we weren’t sure about are held back until a person checks.
EPA testing for PFAS and lithium
EPA’s own nationwide testing (UCMR 5) found these in City of Tyler’s water between Jan 2023 and Oct 2023. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.
- Lithium20 ppbFound in 1 of 8 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)
Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.
What you can do
Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.
Radium and uranium
Found: Gross beta (radioactivity)
What removes it: Reverse osmosis.
More districts: Texas water quality · All states · Something look wrong? Tell us