We read 30 results from City of Plano’s 2024 water quality report. No results over a legal limit; 8 above a health goal or guideline.

Serves about 288,800 people · Water system ID TX0430007 · Read the district’s 2024 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2024 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Bromatesingle sample · range 9.19 to 9.19 · NTMWD Leonard plant · 2024 report, page 119.19 ppb0.1 ppb10 ppbAbove the health goal92x the health goal
Chloriteaverage · NTMWD Wylie plant · 2024 report, page 70.19 ppm0.05 ppm1 ppmAbove the health goal3.7x the health goal
Copper90th percentile of homes tested, 1 over the action level · Customer taps · 2024 report, page 61.01 ppm0.3 ppm1.3 ppm (action level)Above the health goal3.4x the health goal
Gross beta (radioactivity)highest measured · range 5.3 to 5.3 · NTMWD Wylie plant · 2024 report, page 75.3 pCi/L0 pCi/L50 pCi/LAbove the health goalThe health goal is zero
Lead90th percentile of homes tested, 0 over the action level · Customer taps · 2024 report, page 62.97 ppb0.2 ppb15 ppb (action level)Above the health goal15x the health goal
Manganesehighest measured · range 0.03 to 0.08 · NTMWD Wylie plant · 2024 report, page 100.08 ppm—0.05 ppm guidelineAbove the guideline1.6x the guideline (taste, odor or stains; not a health limit)
pHhighest measured · range 7.4 to 8.9 · NTMWD Wylie plant · 2024 report, page 108.9——Outside the normal rangeAlkaline water can leave scale
Total dissolved solidshighest measured · range 271 to 509 · NTMWD Wylie plant · 2024 report, page 10509 ppm—500 ppm guidelineAbove the guideline1x the guideline (taste, odor or stains; not a health limit)
Atrazinehighest measured · range 0.1 to 0.1 · NTMWD Wylie plant · 2024 report, page 80.1 ppb0.15 ppb3 ppbBelow the health goal
Bariumhighest measured · range 0.04 to 0.06 · NTMWD Wylie plant, highest of 2 sources · 2024 report, page 70.06 ppm2 ppm2 ppmBelow the health goal
Chloramineaverage · range 0.1 to 3.88 · Distribution system · 2024 report, page 62.53 ppmNone set4 ppmBelow the legal limit
Chloridehighest measured · range 15.4 to 95.3 · NTMWD Wylie plant · 2024 report, page 1095.3 ppm—250 ppm guidelineWithin the guideline
Chlorine dioxideaverage · printed as 0.027 ppm · NTMWD Wylie plant · 2024 report, page 727 ppbNone set800 ppbBelow the legal limit
Cyanidehighest measured · range 28.5 to 128 · NTMWD Wylie plant, highest of 2 sources · 2024 report, page 7128 ppb150 ppb200 ppbBelow the health goal
Disinfection byproducts (HAA5)highest running annual average · range 12.4 to 36.5 · Distribution system · 2024 report, page 630 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 20.6 to 57.3 · Distribution system · 2024 report, page 641 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.32 to 0.71 · NTMWD Wylie plant, highest of 2 sources · 2024 report, page 70.71 ppm1 ppm4 ppmBelow the health goal
Nitrate (as N)highest measured · range ND to 0.36 · Distribution system · 2024 report, page 60.36 ppm10 ppm10 ppmBelow the health goal
Sulfatehighest measured · range 39.6 to 165 · NTMWD Wylie plant · 2024 report, page 10165 ppm—250 ppm guidelineWithin the guideline
Turbidity (cloudiness)highest measured · NTMWD Wylie plant · 2024 report, page 90.93 NTUNone set1 NTUBelow the legal limit
Alkalinityhighest measured · range 56.5 to 128 · NTMWD Wylie plant · 2024 report, page 10128 ppmNone setNoneNo health limit
Bromodichloromethanehighest measured · range 7.7 to 20.4 · Distribution system · 2024 report, page 620.4 ppbNone setNoneNo health limit
Bromoformhighest measured · range 1.15 to 2.07 · Distribution system · 2024 report, page 62.07 ppbNone setNoneNo health limit
Calciumhighest measured · range 35.4 to 66.5 · NTMWD Wylie plant · 2024 report, page 1066.5 ppmNone setNoneNo health limit
Chloroformhighest measured · range 5.09 to 20.1 · Distribution system · 2024 report, page 620.1 ppbNone setNoneNo health limit
Dibromochloromethanehighest measured · range 5.68 to 14.9 · Distribution system · 2024 report, page 614.9 ppbNone setNoneNo health limit
Hardnesshighest measured · range 6.14 to 11.8 · NTMWD Wylie plant · 2024 report, page 1011.8 gpg (202 ppm)——Very hard
Magnesiumhighest measured · range 5.88 to 9.84 · NTMWD Wylie plant · 2024 report, page 109.84 ppmNone setNoneNo health limit
Nickelhighest measured · range 4.8 to 6.7 · printed as 0.0067 ppm · NTMWD Wylie plant · 2024 report, page 106.7 ppbNone setNoneNo health limit
Sodiumhighest measured · range 35.5 to 88.7 · NTMWD Wylie plant · 2024 report, page 1088.7 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 1 number we weren’t sure about is held back until a person checks.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in City of Plano’s water between Feb 2025 and Nov 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • PFBS3.1 pptFound in 1 of 4 samples · highest resultNo federal limit in force for this one

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Disinfection byproducts

Found: Bromate, Chlorite

What removes it: Carbon block.

See filters that remove it

Lead

Found: Copper, Lead

What removes it: Reverse osmosis or Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Radium and uranium

Found: Gross beta (radioactivity)

What removes it: Reverse osmosis.

See filters that remove it

Sediment or cloudy water

Found: Manganese

What removes it: Oxidation filter.

See filters that remove it

Salty taste / high TDS

Found: Total dissolved solids

What removes it: Reverse osmosis.

See filters that remove it