City of Grand Prairie water quality

Updated 2026-10-22 · Texas · Affiliate disclosure

We read 20 results from City of Grand Prairie’s 2025 water quality report. No results over a legal limit; 8 above a health goal or guideline.

Serves about 201,843 people · Water system ID TX0570048 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Arsenichighest measured · range ND to 1.1 · Fort Worth supply · 2025 report, page 61.1 ppb0.004 ppb10 ppbAbove the health goal275x the health goal
Bromatehighest running annual average · range ND to 13.7 · Fort Worth supply · 2025 report, page 66.17 ppb0.1 ppb10 ppbAbove the health goal62x the health goal
Chloritehighest measured · range 0.04 to 0.27 · Mansfield supply · 2025 report, page 60.27 ppm0.05 ppm1 ppmAbove the health goal5.4x the health goal
Cyanidehighest measured · range ND to 168 · Fort Worth supply, highest of 2 sources · 2025 report, page 6168 ppb150 ppb200 ppbAbove the health goal1.1x the health goal
Gross beta (radioactivity)average · range 7.5 to 7.5 · sampled 2024 · Fort Worth supply · 2025 report, page 67.5 pCi/L0 pCi/L50 pCi/LAbove the health goalThe health goal is zero
Lead90th percentile of 50 homes tested · sampled 2024 · Customer taps (50 sites) · 2025 report, page 51.2 ppb0.2 ppb15 ppb (action level)Above the health goal6x the health goal
Total coliform bacteriahighest month · Grand Prairie distribution system · 2025 report, page 51.53 % positive0 % positive5 % positiveAbove the health goalThe health goal is zero
Uraniumaverage · range 1.6 to 1.6 · sampled 2024 · Fort Worth supply · 2025 report, page 61.6 ppb0.6 ppb30 ppbAbove the health goal2.7x the health goal
Bariumhighest measured · range 0.05 to 0.07 · Fort Worth supply · 2025 report, page 60.07 ppm2 ppm2 ppmBelow the health goal
Chloramineaverage · range 0.6 to 4.7 · Grand Prairie distribution system · 2025 report, page 52.95 ppmNone set4 ppmBelow the legal limit
Copper90th percentile of 50 homes tested · sampled 2024 · Customer taps (50 sites) · 2025 report, page 50.25 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range 4.6 to 24.3 · Grand Prairie distribution system · 2025 report, page 530.3 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 13.6 to 36.2 · Grand Prairie distribution system · 2025 report, page 544.7 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.21 to 0.74 · Fort Worth supply · 2025 report, page 60.74 ppm1 ppm4 ppmBelow the health goal
Nitrate (as N)highest measured · range 0.03 to 1.15 · Grand Prairie system · 2025 report, page 51.15 ppm10 ppm10 ppmBelow the health goal
Nitrite (as N)highest measured · range 0.37 to 0.37 · sampled 2024 · Grand Prairie system · 2025 report, page 50.37 ppm1 ppm1 ppmBelow the health goal
Turbidity (cloudiness)highest measured · Mansfield supply, highest of 2 sources · 2025 report, page 60.51 NTUNone set1 NTUBelow the legal limit
Bromodichloromethaneaverage · range 4.47 to 10.6 · Grand Prairie distribution system · 2025 report, page 56.08 ppbNone setNoneNo health limit
Bromoformaverage · range ND to 6.78 · Grand Prairie distribution system · 2025 report, page 51.99 ppbNone setNoneNo health limit
Chloroformaverage · range 3.11 to 10.5 · Grand Prairie distribution system · 2025 report, page 54.87 ppbNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in City of Grand Prairie’s water between May 2024 and Feb 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • PFOA4.9 pptFound in 2 of 20 samples · highest resultAbove the federal limit that takes effect in 2029 (4 ppt)
  • PFOS82 pptFound in 5 of 20 samples · highest resultAbove the federal limit that takes effect in 2029 (4 ppt)
  • PFHxS3.3 pptFound in 1 of 20 samples · highest resultNo federal limit in force for this one
  • PFBS5.1 pptFound in 9 of 20 samples · highest resultNo federal limit in force for this one
  • Lithium12.1 ppbFound in 2 of 20 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Arsenic

Found: Arsenic

What removes it: Reverse osmosis.

See filters that remove it

Disinfection byproducts

Found: Bromate, Chlorite

What removes it: Carbon block.

See filters that remove it

Radium and uranium

Found: Gross beta (radioactivity), Uranium

What removes it: Reverse osmosis.

See filters that remove it

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Bacteria and viruses

Found: Total coliform bacteria

What removes it: UV purification (and tell your utility).

See filters that remove itDo I need a UV water purifier?

PFAS ("forever chemicals")

Found: PFOA (EPA testing), PFOS (EPA testing)

What removes it: Reverse osmosis.

See filters that remove itWhat water filter removes PFAS?

More districts: Texas water quality · All states · Something look wrong? Tell us