City of Beaumont Water Utility Dept water quality

Updated 2026-10-22 · Texas · Affiliate disclosure

We read 11 results from City of Beaumont Water Utility Dept’s 2025 water quality report. No results over a legal limit; 2 above a health goal or guideline.

Serves about 115,282 people · Water system ID TX1230001 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Cyanideas reported · Treated water · 2025 report, page 4170 ppb150 ppb200 ppbAbove the health goal1.1x the health goal
Lead90th percentile of 204 homes tested, 0 over the action level · Customer taps · 2025 report, page 41 ppb0.2 ppb15 ppb (action level)Above the health goal5x the health goal
Bariumhighest measured · range 0.04 to 0.05 · Treated water · 2025 report, page 40.05 ppm2 ppm2 ppmBelow the health goal
Chloramineaverage · range ND to 4.12 · Distribution system · 2025 report, page 43.24 ppmNone set4 ppmBelow the legal limit
Copper90th percentile of 205 homes tested, 0 over the action level · Customer taps · 2025 report, page 40.04 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range 7.3 to 25.1 · Distribution system · 2025 report, page 422 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 19 to 41.9 · Distribution system · 2025 report, page 433 ppbNone set80 ppbBelow the legal limit
Nitrate (as N)highest measured · range ND to 0.08 · Treated water · 2025 report, page 40.08 ppm10 ppm10 ppmBelow the health goal
Turbidity (cloudiness)highest measured · Surface water plant · 2025 report, page 40.22 NTUNone set1 NTUBelow the legal limit
Dibromochloromethanehighest measured · range ND to 9 · Distribution system · 2025 report, page 49 ppbNone setNoneNo health limit
Nickelhighest measured · range ND to 1.6 · printed as 0.0016 ppm · Treated water · 2025 report, page 41.6 ppbNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 1 number we weren’t sure about is held back until a person checks.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in City of Beaumont Water Utility Dept’s water between Jan 2023 and Oct 2023. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium15.7 ppbFound in 2 of 6 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

More districts: Texas water quality · All states · Something look wrong? Tell us