Consolidated U.D. of Rutherford Co water quality

Updated 2026-10-22 · Tennessee · Affiliate disclosure

We read 19 results from Consolidated U.D. of Rutherford Co’s 2025 water quality report. No results over a legal limit; 4 above a health goal or guideline.

Serves about 221,871 people · Water system ID TN0000791 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Chloriteaverage · Distribution system · 2025 report, page 110.69 ppm0.05 ppm1 ppmAbove the health goal14x the health goal
Lead90th percentile of homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 90.5 ppb0.2 ppb15 ppb (action level)Above the health goal2.5x the health goal
PFOA (a PFAS)average · printed as 0.001500 ug/L · Treatment plant · 2025 report, page 101.5 ppt0.007 ppt4 ppt from 2029Above the health goal214x the health goal
Total coliform bacteriahighest month · range ND to 0.7 · Distribution system · 2025 report, page 120.7 % positive0 % positive5 % positiveAbove the health goalThe health goal is zero
Chlorinehighest running annual average · range 0.4 to 3.7 · Distribution system · 2025 report, page 112.54 ppmNone set4 ppmBelow the legal limit
Chlorine dioxideaverage · range ND to 570 · printed as 0.048 ppm · Treatment plant · 2025 report, page 1148 ppbNone set800 ppbBelow the legal limit
Copper90th percentile of homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 90.1 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range 6 to 55 · Distribution system · 2025 report, page 946.8 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 11.4 to 104 · Distribution system · 2025 report, page 956.9 ppbNone set80 ppbBelow the legal limit
Fluorideaverage · range 0.03 to 0.75 · Treatment plant · 2025 report, page 130.28 ppm1 ppm4 ppmBelow the health goal
Nitrate (as N)single sample · Treatment plant · 2025 report, page 130.22 ppm10 ppm10 ppmBelow the health goal
Turbidity (cloudiness)highest measured · range 0.02 to 0.28 · Treatment plant · 2025 report, page 100.28 NTUNone set1 NTUBelow the legal limit
Bromodichloromethanesingle sample · printed as 0.0024 ppm · Distribution system · 2025 report, page 122.4 ppbNone setNoneNo health limit
Chloroformsingle sample · printed as 0.0165 ppm · Distribution system · 2025 report, page 1216.5 ppbNone setNoneNo health limit
PFBA (a PFAS)average · printed as 0.001875 ug/L · Treatment plant · 2025 report, page 101.88 pptNone setNoneNo health limit
PFBS (a PFAS)average · printed as 0.002325 ug/L · Treatment plant · 2025 report, page 102.33 pptNone setNoneNo health limit
PFHxA (a PFAS)average · printed as 0.002275 ug/L · Treatment plant · 2025 report, page 102.28 pptNone setNoneNo health limit
PFPeA (a PFAS)average · printed as 0.00125 ug/L · Treatment plant · 2025 report, page 101.25 pptNone setNoneNo health limit
Sodiumsingle sample · Treatment plant · 2025 report, page 1311.9 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Consolidated U.D. of Rutherford Co’s water between Jan 2023 and Jan 2024. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • PFBS5.8 pptFound in 1 of 4 samples · highest resultNo federal limit in force for this one

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Disinfection byproducts

Found: Chlorite

What removes it: Carbon block.

See filters that remove it

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

PFAS ("forever chemicals")

Found: PFOA (a PFAS)

What removes it: Reverse osmosis.

See filters that remove itWhat water filter removes PFAS?

Bacteria and viruses

Found: Total coliform bacteria

What removes it: UV purification (and tell your utility).

See filters that remove itDo I need a UV water purifier?

More districts: Tennessee water quality · All states · Something look wrong? Tell us