We read 22 results from Columbia City of (Sc4010001)’s 2025 water quality report. No results over a legal limit; 7 above a health goal or guideline.
Serves about 319,500 people · Water system ID SC4010001 · Read the district’s 2025 report (opens in a new tab)
Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.
Results from the 2025 report
Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.
| Contaminant | Result | Health goal | Legal limit | What it means |
|---|---|---|---|---|
| Chloritehighest measured · range ND to 0.9 · Canal Plant, highest of 2 sources · 2025 report, page 2 | 0.9 ppm | 0.05 ppm | 1 ppm | Above the health goal18x the health goal |
| Gross alpha (radioactivity)highest measured · range ND to 0.87 · sampled 2021 · Treatment plants · 2025 report, page 3 | 0.87 pCi/L | 0 pCi/L | 15 pCi/L | Above the health goalThe health goal is zero |
| Lead90th percentile of 50 homes tested, 1 over the action level · sampled 2023 · Customer taps · 2025 report, page 2 | 6 ppb | 0.2 ppb | 15 ppb (action level) | Above the health goal30x the health goal |
| PFOA (a PFAS)average · range 4.8 to 6.9 · printed as 0.0058 ppb · Canal Plant, highest of 2 sources · 2025 report, page 4 | 5.8 ppt | 0.007 ppt | 4 ppt from 2029 | Above the federal limit that takes effect in 20291.5x the 4 ppt federal limit that takes effect in 2029Not a violation yet: EPA's 4 ppt limit is final, but water systems don't have to meet it until 2029. |
| PFOS (a PFAS)average · range 6.2 to 8.6 · printed as 0.0076 ppb · Canal Plant, highest of 2 sources · 2025 report, page 4 | 7.6 ppt | 1 ppt | 4 ppt from 2029 | Above the federal limit that takes effect in 20291.9x the 4 ppt federal limit that takes effect in 2029Not a violation yet: EPA's 4 ppt limit is final, but water systems don't have to meet it until 2029. |
| Radium (combined 226 + 228)highest measured · range ND to 0.74 · sampled 2021 · Treatment plants · 2025 report, page 3 | 0.74 pCi/L | 0 pCi/L | 5 pCi/L | Above the health goalThe health goal is zero |
| Total coliform bacteriahighest month · range ND to 3.4 · Distribution system · 2025 report, page 2 | 3.4 % positive | 0 % positive | 5 % positive | Above the health goalThe health goal is zero |
| Chloraminehighest running annual average · range ND to 4.5 · Distribution system · 2025 report, page 2 | 2.7 ppm | None set | 4 ppm | Below the legal limit |
| Chlorideaverage · range 7.72 to 13.9 · System · 2025 report, page 4 | 10.8 ppm | — | 250 ppm guideline | Within the guideline |
| Copper90th percentile of 50 homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 2 | 0.17 ppm | 0.3 ppm | 1.3 ppm (action level) | Below the health goal |
| Disinfection byproducts (HAA5)highest running annual average · range ND to 31.8 · Distribution system · 2025 report, page 2 | 24 ppb | None set | 60 ppb | Below the legal limit |
| Disinfection byproducts (TTHM)highest running annual average · range 5.5 to 48 · Distribution system · 2025 report, page 2 | 30 ppb | None set | 80 ppb | Below the legal limit |
| Fluoridehighest measured · range 0.05 to 0.79 · Treatment plants · 2025 report, page 2 | 0.79 ppm | 1 ppm | 4 ppm | Below the health goal |
| GenX (HFPO-DA, a PFAS)average · range 7.1 to 9.2 · printed as 0.0080 ppb · Lake Plant · 2025 report, page 4 | 8 ppt | None set | 10 ppt from 2029 | Below the legal limit |
| Nitrate (as N)highest measured · range ND to 0.52 · Treatment plants · 2025 report, page 2 | 0.52 ppm | 10 ppm | 10 ppm | Below the health goal |
| pHaverage · range 7.5 to 8.6 · System · 2025 report, page 4 | 7.9 | — | — | Normal range |
| Seleniumhighest measured · range 4.2 to 5.1 · Treatment plants · 2025 report, page 2 | 5.1 ppb | 30 ppb | 50 ppb | Below the health goal |
| Sulfateaverage · range 14.2 to 25.3 · System · 2025 report, page 4 | 18.1 ppm | — | 250 ppm guideline | Within the guideline |
| Turbidity (cloudiness)highest measured · Canal Plant, highest of 2 sources · 2025 report, page 2 | 0.13 NTU | None set | 1 NTU | Below the legal limit |
| Hardnessaverage · range 1.17 to 2.75 · System · 2025 report, page 4 | 2.11 gpg (36 ppm) | — | — | Soft |
| PFBS (a PFAS)average · range 3.5 to 5.2 · printed as 0.0043 ppb · Canal Plant · 2025 report, page 4 | 4.3 ppt | None set | None | No health limit |
| Sodiumaverage · range 5 to 12 · System · 2025 report, page 4 | 7.3 ppm | None set | None | No health limit |
Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.
EPA testing for PFAS and lithium
EPA’s own nationwide testing (UCMR 5) found these in Columbia City of (Sc4010001)’s water between Dec 2024 and Sep 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.
- PFOA6.9 pptFound in 6 of 8 samples · highest resultAbove the federal limit that takes effect in 2029 (4 ppt)
- PFOS8.6 pptFound in 6 of 8 samples · highest resultAbove the federal limit that takes effect in 2029 (4 ppt)
- HFPO-DA (GenX)9.2 pptFound in 5 of 8 samples · highest resultNo federal limit in force for this one
- PFBS5.2 pptFound in 4 of 8 samples · highest resultNo federal limit in force for this one
Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.
What you can do
Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.
Radium and uranium
Found: Gross alpha (radioactivity), Radium (combined 226 + 228)
What removes it: Reverse osmosis.
Lead
Found: Lead
What removes it: Certified carbon block or RO.
PFAS ("forever chemicals")
Found: PFOA (a PFAS), PFOS (a PFAS), PFOA (EPA testing), PFOS (EPA testing)
What removes it: Reverse osmosis.
Bacteria and viruses
Found: Total coliform bacteria
What removes it: UV purification (and tell your utility).
More districts: South Carolina water quality · All states · Something look wrong? Tell us