Los Lunas Water System water quality

Updated 2026-10-22 · New Mexico · Affiliate disclosure

We read 11 results from Los Lunas Water System’s 2025 water quality report. No results over a legal limit; 5 above a health goal or guideline.

Serves about 19,400 people · Water system ID NM3525332 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Copper90th percentile of homes tested, 0 over the action level · sampled 2024 · Customer taps · 2025 report, page 30.44 ppm0.3 ppm1.3 ppm (action level)Above the health goal1.5x the health goal
Gross beta (radioactivity)highest measured · range 5.8 to 7.94 · 2025 report, page 37.94 pCi/L0 pCi/L50 pCi/LAbove the health goalThe health goal is zero
Lead90th percentile of homes tested, 0 over the action level · sampled 2024 · Customer taps · 2025 report, page 35 ppb0.2 ppb15 ppb (action level)Above the health goal25x the health goal
Radium (combined 226 + 228)highest measured · range ND to 0.76 · 2025 report, page 30.76 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Uraniumhighest measured · range 6.8 to 7.8 · 2025 report, page 37.8 ppb0.6 ppb30 ppbAbove the health goal13x the health goal
Bariumhighest measured · range 0.02 to 0.02 · 2025 report, page 30.02 ppm2 ppm2 ppmBelow the health goal
Chlorinehighest measured · range 0.5 to 0.6 · 2025 report, page 30.6 ppmNone set4 ppmBelow the legal limit
Disinfection byproducts (HAA5)as reported · range ND to 0.93 · 2025 report, page 31 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)as reported · range ND to 0.7 · 2025 report, page 31 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.81 to 0.88 · 2025 report, page 30.88 ppm1 ppm4 ppmBelow the health goal
Seleniumhighest measured · range 1.1 to 2.1 · 2025 report, page 32.1 ppb30 ppb50 ppbBelow the health goal

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 1 number we weren’t sure about is held back until a person checks.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Los Lunas Water System’s water between Aug 2023 and Aug 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium34 ppbFound in 10 of 10 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Lead

Found: Copper, Lead

What removes it: Reverse osmosis or Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Radium and uranium

Found: Gross beta (radioactivity), Radium (combined 226 + 228), Uranium

What removes it: Reverse osmosis.

See filters that remove it

More districts: New Mexico water quality · All states · Something look wrong? Tell us