City of Brandon water quality

Updated 2026-10-22 · Mississippi · Affiliate disclosure

We read 11 results from City of Brandon’s 2025 water quality report. No results over a legal limit; 2 above a health goal or guideline.

Serves about 31,548 people · Water system ID MS0610003 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Arsenichighest measured · range ND to 0.5 · listed as a violation in the report · printed as 0.0005 ppm · Wells · 2025 report, page 20.5 ppb0.004 ppb10 ppbAbove the health goal125x the health goal
Lead90th percentile of homes tested · listed as a violation in the report · printed as 0.002 mg/L · Customer taps · 2025 report, page 32 ppb0.2 ppb15 ppb (action level)Above the health goal10x the health goal
Bariumhighest measured · range 0.0016 to 0.0028 · listed as a violation in the report · Wells · 2025 report, page 20.0028 ppm2 ppm2 ppmBelow the health goal
Chlorineas reported · range 0.9 to 3.8 · listed as a violation in the report · Distribution system · 2025 report, page 32.3 ppmNone set4 ppmBelow the legal limit
Chromium (total)highest measured · range 0.7 to 2.8 · listed as a violation in the report · printed as 0.0028 ppm · Wells · 2025 report, page 22.8 ppbNone set100 ppbBelow the legal limit
Copper90th percentile of homes tested · listed as a violation in the report · Customer taps · 2025 report, page 30.3 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest measured · range 11.1 to 16.7 · listed as a violation in the report · Distribution system · 2025 report, page 316.7 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest measured · range 26.9 to 33.4 · listed as a violation in the report · Distribution system · 2025 report, page 333.4 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.1 to 0.16 · listed as a violation in the report · Wells · 2025 report, page 20.16 ppm1 ppm4 ppmBelow the health goal
Lithiumhighest measured · range 22.5 to 22.5 · listed as a violation in the report · Wells (UCMR 5) · 2025 report, page 322.5 ppbNone setNoneNo health limit
Sodiumhighest measured · range 80.3 to 139 · listed as a violation in the report · sampled 2023 · Wells · 2025 report, page 3139 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in City of Brandon’s water between Aug 2024 and Jan 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium23.1 ppbFound in 14 of 17 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Arsenic

Found: Arsenic

What removes it: Reverse osmosis.

See filters that remove it

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

More districts: Mississippi water quality · All states · Something look wrong? Tell us