We read 21 results from Texas County Pwsd 1’s 2025 water quality report. No results over a legal limit; 4 above a health goal or guideline.
Serves about 3,335 people · Water system ID MO4024606 · Read the district’s 2025 report (opens in a new tab)
Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.
Results from the 2025 report
Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.
| Contaminant | Result | Health goal | Legal limit | What it means |
|---|---|---|---|---|
| Gross alpha (radioactivity)highest measured · range 5.7 to 5.7 · highest of 2 sources · 2025 report, page 2 | 5.7 pCi/L | 0 pCi/L | 15 pCi/L | Above the health goalThe health goal is zero |
| Manganesehighest measured · range 0.0029 to 0.4 · 2025 report, page 3 | 0.4 ppm | — | 0.05 ppm guideline | Above the guideline8.1x the guideline (taste, odor or stains; not a health limit) |
| Radium (combined 226 + 228)highest measured · range 1.1 to 1.1 · 2025 report, page 2 | 1.1 pCi/L | 0 pCi/L | 5 pCi/L | Above the health goalThe health goal is zero |
| Radium-226highest measured · range 1.1 to 1.1 · 2025 report, page 2 | 1.1 pCi/L | 0.05 pCi/L | 5 pCi/L | Above the health goal22x the health goal |
| Aluminumhighest measured · range ND to 0.01 · 2025 report, page 3 | 0.01 ppm | — | 0.2 ppm guideline | Within the guideline |
| Bariumhighest measured · range 0.05 to 0.05 · 2025 report, page 2 | 0.05 ppm | 2 ppm | 2 ppm | Below the health goal |
| Copper90th percentile of homes tested, 0 over the action level · Customer taps · 2025 report, page 2 | 0.01 ppm | 0.3 ppm | 1.3 ppm (action level) | Below the health goal |
| Ironhighest measured · range 0.03 to 0.25 · 2025 report, page 3 | 0.25 ppm | — | 0.3 ppm guideline | Within the guideline |
| Lead90th percentile of homes tested, 0 over the action level · Customer taps · 2025 report, page 2 | Not detected | 0.2 ppb | 15 ppb (action level) | Not detected |
| Nitrate (as N)highest measured · range ND to 0.1 · 2025 report, page 2 | 0.1 ppm | 10 ppm | 10 ppm | Below the health goal |
| pHhighest measured · range 7.87 to 8.21 · 2025 report, page 3 | 8.21 | — | — | Normal range |
| Sulfatehighest measured · range ND to 17.3 · 2025 report, page 3 | 17.3 ppm | — | 250 ppm guideline | Within the guideline |
| Total dissolved solidshighest measured · range 260 to 264 · 2025 report, page 3 | 264 ppm | — | 500 ppm guideline | Within the guideline |
| Zinchighest measured · range 0.04 to 0.05 · 2025 report, page 3 | 0.05 ppm | — | 5 ppm guideline | Within the guideline |
| Alkalinityhighest measured · range 263 to 270 · 2025 report, page 3 | 270 ppm | None set | None | No health limit |
| Calciumhighest measured · range 51.6 to 55 · 2025 report, page 3 | 55 ppm | None set | None | No health limit |
| Hardnesshighest measured · range 15.3 to 16.2 · 2025 report, page 3 | 16.2 gpg (277 ppm) | — | — | Very hard |
| Magnesiumhighest measured · range 32.2 to 34 · 2025 report, page 3 | 34 ppm | None set | None | No health limit |
| Nickelhighest measured · range 2.19 to 2.83 · printed as 0.00283 MG/L · 2025 report, page 3 | 2.83 ppb | None set | None | No health limit |
| Potassiumhighest measured · range ND to 1.18 · 2025 report, page 3 | 1.18 ppm | None set | None | No health limit |
| Sodiumhighest measured · range 2.33 to 2.52 · 2025 report, page 3 | 2.52 ppm | None set | None | No health limit |
Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.
What you can do
Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.
Radium and uranium
Found: Gross alpha (radioactivity), Radium (combined 226 + 228), Radium-226
What removes it: Reverse osmosis.
Sediment or cloudy water
Found: Manganese
What removes it: Oxidation filter.
More districts: Missouri water quality · All states · Something look wrong? Tell us