Scott City Pws water quality

Updated 2026-10-22 · Missouri · Affiliate disclosure

We read 25 results from Scott City Pws’s 2025 water quality report. No results over a legal limit; 2 above a health goal or guideline.

Serves about 4,653 people · Water system ID MO4010726 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Lead90th percentile of homes tested, 0 over the action level · Customer taps · 2025 report, page 21.25 ppb0.2 ppb15 ppb (action level)Above the health goal6.3x the health goal
Radium-228highest measured · range 1.1 to 1.1 · sampled 2021 · 2025 report, page 21.1 pCi/L0.02 pCi/L5 pCi/LAbove the health goal58x the health goal
2,4-D (weed killer)highest measured · range 0.14 to 0.14 · 2025 report, page 20.14 ppb70 ppb70 ppbBelow the health goal
Aluminumhighest measured · range 0.02 to 0.04 · sampled 2024 · 2025 report, page 30.04 ppm—0.2 ppm guidelineWithin the guideline
Bariumhighest measured · range 0.48 to 0.5 · sampled 2024 · 2025 report, page 20.5 ppm2 ppm2 ppmBelow the health goal
Chloridehighest measured · range 29.6 to 35 · sampled 2024 · 2025 report, page 335 ppm—250 ppm guidelineWithin the guideline
Copper90th percentile of homes tested, 0 over the action level · Customer taps · 2025 report, page 20.15 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range 1.3 to 1.3 · DBPDUAL-01 · 2025 report, page 21 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 25.4 to 25.4 · DBPDUAL-01 · 2025 report, page 225 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.18 to 0.52 · sampled 2024 · 2025 report, page 20.52 ppm1 ppm4 ppmBelow the health goal
Ironhighest measured · range 0.0061 to 0.03 · sampled 2024 · 2025 report, page 30.03 ppm—0.3 ppm guidelineWithin the guideline
Manganesehighest measured · range ND to 0.0012 · sampled 2024 · 2025 report, page 30.0012 ppm—0.05 ppm guidelineWithin the guideline
PFHxS (a PFAS)highest measured · range 8 to 8 · 2025 report, page 38 pptNone set10 ppt from 2029Below the legal limit
pHhighest measured · range 7.86 to 8.15 · sampled 2024 · 2025 report, page 38.15——Normal range
Sulfatehighest measured · range 36.6 to 38.1 · sampled 2024 · 2025 report, page 338.1 ppm—250 ppm guidelineWithin the guideline
Total dissolved solidshighest measured · range 390 to 405 · sampled 2024 · 2025 report, page 3405 ppm—500 ppm guidelineWithin the guideline
Zinchighest measured · range 0.0055 to 0.02 · sampled 2024 · 2025 report, page 30.02 ppm—5 ppm guidelineWithin the guideline
Alkalinityhighest measured · range 295 to 375 · sampled 2024 · 2025 report, page 3375 ppmNone setNoneNo health limit
Calciumhighest measured · range 75.2 to 76.6 · sampled 2024 · 2025 report, page 376.6 ppmNone setNoneNo health limit
Hardnesshighest measured · range 17 to 17.3 · sampled 2024 · 2025 report, page 317.3 gpg (295 ppm)——Very hard
Lithiumhighest measured · range 12.6 to 12.6 · 2025 report, page 312.6 ppbNone setNoneNo health limit
Magnesiumhighest measured · range 24.9 to 25.3 · sampled 2024 · 2025 report, page 325.3 ppmNone setNoneNo health limit
Nickelhighest measured · range 2.13 to 2.3 · printed as 0.0023 MG/L · sampled 2024 · 2025 report, page 32.3 ppbNone setNoneNo health limit
Potassiumhighest measured · range 1.99 to 2.04 · sampled 2024 · 2025 report, page 32.04 ppmNone setNoneNo health limit
Sodiumhighest measured · range 27.6 to 27.9 · sampled 2024 · 2025 report, page 327.9 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 2 numbers we weren’t sure about are held back until a person checks.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Scott City Pws’s water between May 2025 and Nov 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • PFHxS8.4 pptFound in 2 of 2 samples · highest resultNo federal limit in force for this one
  • Lithium12.6 ppbFound in 2 of 2 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Radium and uranium

Found: Radium-228

What removes it: Reverse osmosis.

See filters that remove it

More districts: Missouri water quality · All states · Something look wrong? Tell us