Peculiar Pws water quality

Updated 2026-10-22 · Missouri · Affiliate disclosure

We read 10 results from Peculiar Pws’s 2025 water quality report. No results over a legal limit; 1 above a health goal or guideline.

Serves about 6,226 people · Water system ID MO1010633 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Atrazinehighest measured · range ND to 0.27 · Purchased water (wholesaler) · 2025 report, page 30.27 ppb0.15 ppb3 ppbAbove the health goal1.8x the health goal
Bariumhighest measured · range 0.01 to 0.01 · Purchased water (wholesaler) · 2025 report, page 30.01 ppm2 ppm2 ppmBelow the health goal
Copper90th percentile of homes tested, 0 over the action level · Customer taps · 2025 report, page 20.01 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range 25.4 to 25.4 · DBPDUAL-02, highest of 2 sources · 2025 report, page 225 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 13 to 13 · DBPDUAL-02, highest of 2 sources · 2025 report, page 213 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.75 to 0.75 · Purchased water (wholesaler) · 2025 report, page 30.75 ppm1 ppm4 ppmBelow the health goal
Lead90th percentile of homes tested, 0 over the action level · Customer taps · 2025 report, page 2Not detected0.2 ppb15 ppb (action level)Not detected
Nitrate (as N)highest measured · range 0.93 to 0.93 · Purchased water (wholesaler) · 2025 report, page 30.93 ppm10 ppm10 ppmBelow the health goal
Seleniumhighest measured · range 1.95 to 1.95 · Purchased water (wholesaler) · 2025 report, page 31.95 ppb30 ppb50 ppbBelow the health goal
Lithiumhighest measured · range 36 to 50 · sampled 2024 · highest of 2 sources · 2025 report, page 450 ppbNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 23 numbers we weren’t sure about are held back until a person checks.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Peculiar Pws’s water between Jan 2024 and Oct 2024. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium50 ppbFound in 4 of 4 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Industrial chemicals and pesticides

Found: Atrazine

What removes it: Carbon block or RO.

See filters that remove it

More districts: Missouri water quality · All states · Something look wrong? Tell us