Lagrange Pws water quality

Updated 2026-10-22 · Missouri · Affiliate disclosure

We read 21 results from Lagrange Pws’s 2025 water quality report. No results over a legal limit; 2 above a health goal or guideline.

Serves about 874 people · Water system ID MO2010440 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Copper90th percentile of homes tested, 1 over the action level · sampled 2024 · Customer taps · 2025 report, page 20.73 ppm0.3 ppm1.3 ppm (action level)Above the health goal2.4x the health goal
Lead90th percentile of homes tested, 1 over the action level · sampled 2024 · Customer taps · 2025 report, page 21.81 ppb0.2 ppb15 ppb (action level)Above the health goal9x the health goal
Aluminumhighest measured · range 0.01 to 0.01 · 2025 report, page 30.01 ppm—0.2 ppm guidelineWithin the guideline
Bariumhighest measured · range 0.05 to 0.05 · 2025 report, page 20.05 ppm2 ppm2 ppmBelow the health goal
Chloridehighest measured · range 27.3 to 27.3 · 2025 report, page 327.3 ppm—250 ppm guidelineWithin the guideline
Disinfection byproducts (HAA5)highest running annual average · range 9.06 to 40.4 · DBPDUAL-01, highest of 2 sources · 2025 report, page 241 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 56.7 to 80.7 · DBPDUAL-02 · 2025 report, page 265 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.74 to 0.74 · 2025 report, page 20.74 ppm1 ppm4 ppmBelow the health goal
Manganesehighest measured · range 0.002 to 0.002 · 2025 report, page 30.002 ppm—0.05 ppm guidelineWithin the guideline
Nitrate (as N)highest measured · range 0.12 to 0.12 · 2025 report, page 20.12 ppm10 ppm10 ppmBelow the health goal
pHhighest measured · range 7.71 to 7.71 · 2025 report, page 37.71——Normal range
Sulfatehighest measured · range 32.9 to 32.9 · 2025 report, page 332.9 ppm—250 ppm guidelineWithin the guideline
Total dissolved solidshighest measured · range 252 to 252 · 2025 report, page 3252 ppm—500 ppm guidelineWithin the guideline
Zinchighest measured · range 0.003 to 0.003 · 2025 report, page 30.003 ppm—5 ppm guidelineWithin the guideline
Alkalinityhighest measured · range 222 to 222 · 2025 report, page 3222 ppmNone setNoneNo health limit
Calciumhighest measured · range 63.9 to 63.9 · 2025 report, page 363.9 ppmNone setNoneNo health limit
Hardnesshighest measured · range 14.3 to 14.3 · 2025 report, page 314.3 gpg (245 ppm)——Very hard
Magnesiumhighest measured · range 20.7 to 20.7 · 2025 report, page 320.7 ppmNone setNoneNo health limit
Nickelhighest measured · range 1.77 to 1.77 · printed as 0.00177 MG/L · 2025 report, page 31.77 ppbNone setNoneNo health limit
Potassiumhighest measured · range 2.85 to 2.85 · 2025 report, page 32.85 ppmNone setNoneNo health limit
Sodiumhighest measured · range 13 to 13 · 2025 report, page 313 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 1 number we weren’t sure about is held back until a person checks.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Lead

Found: Copper, Lead

What removes it: Reverse osmosis or Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

More districts: Missouri water quality · All states · Something look wrong? Tell us