Jasper County Pwsd 1 water quality

Updated 2026-10-22 · Missouri · Affiliate disclosure

We read 24 results from Jasper County Pwsd 1’s 2025 water quality report. No results over a legal limit; 4 above a health goal or guideline.

Serves about 5,500 people · Water system ID MO5024286 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Gross alpha (radioactivity)highest measured · range 5 to 5 · 2025 report, page 25 pCi/L0 pCi/L15 pCi/LAbove the health goalThe health goal is zero
Lead90th percentile of homes tested, 0 over the action level · Customer taps · 2025 report, page 22.82 ppb0.2 ppb15 ppb (action level)Above the health goal14x the health goal
Radium (combined 226 + 228)highest measured · range 1.6 to 1.6 · 2025 report, page 21.6 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Radium-226highest measured · range 1.6 to 1.6 · 2025 report, page 21.6 pCi/L0.05 pCi/L5 pCi/LAbove the health goal32x the health goal
Bariumhighest measured · range 0.11 to 0.15 · sampled 2024 · 2025 report, page 20.15 ppm2 ppm2 ppmBelow the health goal
Chloridehighest measured · range 5.02 to 20.6 · sampled 2024 · 2025 report, page 320.6 ppm—250 ppm guidelineWithin the guideline
Copper90th percentile of homes tested, 0 over the action level · Customer taps · 2025 report, page 20.06 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (TTHM)highest running annual average · range 1.58 to 1.58 · DBPDUAL-01 · 2025 report, page 22 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.16 to 0.41 · sampled 2024 · 2025 report, page 20.41 ppm1 ppm4 ppmBelow the health goal
Ironhighest measured · range ND to 0.01 · sampled 2024 · 2025 report, page 30.01 ppm—0.3 ppm guidelineWithin the guideline
Manganesehighest measured · range 0.001 to 0.0027 · sampled 2024 · 2025 report, page 30.0027 ppm—0.05 ppm guidelineWithin the guideline
Nitrate (as N)highest measured · range ND to 0.02 · 2025 report, page 20.02 ppm10 ppm10 ppmBelow the health goal
pHhighest measured · range 7.96 to 8.17 · sampled 2024 · 2025 report, page 38.17——Normal range
Sulfatehighest measured · range 13.9 to 16.5 · sampled 2024 · 2025 report, page 316.5 ppm—250 ppm guidelineWithin the guideline
Total dissolved solidshighest measured · range 149 to 197 · sampled 2024 · 2025 report, page 3197 ppm—500 ppm guidelineWithin the guideline
Zinchighest measured · range 0.0044 to 0.02 · sampled 2024 · 2025 report, page 30.02 ppm—5 ppm guidelineWithin the guideline
Alkalinityhighest measured · range 134 to 147 · sampled 2024 · 2025 report, page 3147 ppmNone setNoneNo health limit
Calciumhighest measured · range 27.7 to 29.7 · sampled 2024 · 2025 report, page 329.7 ppmNone setNoneNo health limit
Hardnesshighest measured · range 7.25 to 7.84 · sampled 2024 · 2025 report, page 37.84 gpg (134 ppm)——Hard
Lithiumhighest measured · range ND to 30.7 · UCMR 5 testing, highest of 2 sources · 2025 report, page 230.7 ppbNone setNoneNo health limit
Magnesiumhighest measured · range 13.4 to 14.5 · sampled 2024 · 2025 report, page 314.5 ppmNone setNoneNo health limit
Nickelhighest measured · range 1 to 1.04 · printed as 0.00104 MG/L · sampled 2024 · 2025 report, page 31.04 ppbNone setNoneNo health limit
Potassiumhighest measured · range 1.6 to 2.63 · sampled 2024 · 2025 report, page 32.63 ppmNone setNoneNo health limit
Sodiumhighest measured · range 4.39 to 18.8 · sampled 2024 · 2025 report, page 318.8 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 1 number we weren’t sure about is held back until a person checks.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Jasper County Pwsd 1’s water between May 2025 and Nov 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium30.7 ppbFound in 6 of 8 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Radium and uranium

Found: Gross alpha (radioactivity), Radium (combined 226 + 228), Radium-226

What removes it: Reverse osmosis.

See filters that remove it

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

More districts: Missouri water quality · All states · Something look wrong? Tell us