We read 22 results from Cedar County Pwsd 1’s 2025 water quality report. No results over a legal limit; 4 above a health goal or guideline.

Serves about 1,650 people · Water system ID MO5024120 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Gross alpha (radioactivity)highest measured · range 7 to 7 · sampled 2024 · 2025 report, page 27 pCi/L0 pCi/L15 pCi/LAbove the health goalThe health goal is zero
Radium (combined 226 + 228)highest measured · range 5 to 5 · sampled 2024 · 2025 report, page 25 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Radium-226highest measured · range 3.8 to 3.8 · sampled 2024 · 2025 report, page 23.8 pCi/L0.05 pCi/L5 pCi/LAbove the health goal76x the health goal
Radium-228highest measured · range 1.2 to 1.2 · sampled 2024 · 2025 report, page 21.2 pCi/L0.02 pCi/L5 pCi/LAbove the health goal63x the health goal
Bariumhighest measured · range 0.16 to 0.16 · 2025 report, page 20.16 ppm2 ppm2 ppmBelow the health goal
Chloridehighest measured · range 121 to 121 · 2025 report, page 3121 ppm—250 ppm guidelineWithin the guideline
Copper90th percentile of homes tested, 0 over the action level · sampled 2024 · Customer taps · 2025 report, page 20.03 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Fluoridehighest measured · range 0.33 to 0.33 · 2025 report, page 20.33 ppm1 ppm4 ppmBelow the health goal
Ironhighest measured · range 0.22 to 0.22 · 2025 report, page 30.22 ppm—0.3 ppm guidelineWithin the guideline
Lead90th percentile of homes tested, 0 over the action level · sampled 2024 · Customer taps · 2025 report, page 2Not detected0.2 ppb15 ppb (action level)Not detected
Manganesehighest measured · range 0.003 to 0.003 · 2025 report, page 30.003 ppm—0.05 ppm guidelineWithin the guideline
pHhighest measured · range 7.96 to 7.96 · 2025 report, page 37.96——Normal range
Sulfatehighest measured · range 24.2 to 24.2 · 2025 report, page 324.2 ppm—250 ppm guidelineWithin the guideline
Total dissolved solidshighest measured · range 320 to 320 · 2025 report, page 3320 ppm—500 ppm guidelineWithin the guideline
Zinchighest measured · range 0.02 to 0.02 · 2025 report, page 30.02 ppm—5 ppm guidelineWithin the guideline
Alkalinityhighest measured · range 159 to 159 · 2025 report, page 3159 ppmNone setNoneNo health limit
Calciumhighest measured · range 40.9 to 40.9 · 2025 report, page 340.9 ppmNone setNoneNo health limit
Hardnesshighest measured · range 10.2 to 10.2 · 2025 report, page 310.2 gpg (175 ppm)——Hard
Magnesiumhighest measured · range 17.7 to 17.7 · 2025 report, page 317.7 ppmNone setNoneNo health limit
Nickelhighest measured · range 1.3 to 1.3 · printed as 0.0013 MG/L · 2025 report, page 31.3 ppbNone setNoneNo health limit
Potassiumhighest measured · range 4.36 to 4.36 · 2025 report, page 34.36 ppmNone setNoneNo health limit
Sodiumhighest measured · range 69.4 to 69.4 · 2025 report, page 369.4 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Radium and uranium

Found: Gross alpha (radioactivity), Radium (combined 226 + 228), Radium-226, Radium-228

What removes it: Reverse osmosis.

See filters that remove it

More districts: Missouri water quality · All states · Something look wrong? Tell us