Breckenridge Pws water quality

Updated 2026-10-22 · Missouri · Affiliate disclosure

We read 24 results from Breckenridge Pws’s 2025 water quality report. No results over a legal limit; 3 above a health goal or guideline.

Serves about 333 people · Water system ID MO1010099 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Copper90th percentile of homes tested, 0 over the action level · Customer taps · 2025 report, page 20.56 ppm0.3 ppm1.3 ppm (action level)Above the health goal1.9x the health goal
Lead90th percentile of homes tested, 0 over the action level · Customer taps · 2025 report, page 210.8 ppb0.2 ppb15 ppb (action level)Above the health goal54x the health goal
Radium (combined 226 + 228)highest measured · range 1.7 to 1.7 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 21.7 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Aluminumhighest measured · range 0.02 to 0.02 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 30.02 ppm—0.2 ppm guidelineWithin the guideline
Bariumhighest measured · range 0.41 to 0.41 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 20.41 ppm2 ppm2 ppmBelow the health goal
Chloridehighest measured · range 33.1 to 33.1 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 333.1 ppm—250 ppm guidelineWithin the guideline
Disinfection byproducts (HAA5)highest running annual average · range 23.5 to 36.3 · Purchased water: Distribution system, highest of 4 sources · 2025 report, page 333 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 17.1 to 90.7 · Purchased water: Distribution system, highest of 4 sources · 2025 report, page 372 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.18 to 0.18 · sampled 2023 · Purchased water (wholesaler) · 2025 report, page 20.18 ppm1 ppm4 ppmBelow the health goal
Ironhighest measured · range 0.03 to 0.03 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 30.03 ppm—0.3 ppm guidelineWithin the guideline
Manganesehighest measured · range 0.002 to 0.002 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 30.002 ppm—0.05 ppm guidelineWithin the guideline
Nitrate (as N)highest measured · range 0.4 to 0.4 · Purchased water (wholesaler) · 2025 report, page 20.4 ppm10 ppm10 ppmBelow the health goal
pHhighest measured · range 8.24 to 8.24 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 38.24——Normal range
Sulfatehighest measured · range 19 to 19 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 319 ppm—250 ppm guidelineWithin the guideline
Total dissolved solidshighest measured · range 402 to 402 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 3402 ppm—500 ppm guidelineWithin the guideline
Zinchighest measured · range 0.0092 to 0.0092 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 30.0092 ppm—5 ppm guidelineWithin the guideline
Alkalinityhighest measured · range 372 to 372 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 3372 ppmNone setNoneNo health limit
Calciumhighest measured · range 84.8 to 84.8 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 384.8 ppmNone setNoneNo health limit
Hardnesshighest measured · range 15.4 to 15.4 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 315.4 gpg (263 ppm)——Very hard
Lithiumhighest measured · range 22 to 28.8 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 328.8 ppbNone setNoneNo health limit
Magnesiumhighest measured · range 12.6 to 12.6 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 312.6 ppmNone setNoneNo health limit
Nickelhighest measured · range 1.9 to 1.9 · printed as 0.0019 MG/L · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 31.9 ppbNone setNoneNo health limit
Potassiumhighest measured · range 2.62 to 2.62 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 32.62 ppmNone setNoneNo health limit
Sodiumhighest measured · range 52.4 to 52.4 · sampled 2024 · Purchased water (wholesaler) · 2025 report, page 352.4 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Lead

Found: Copper, Lead

What removes it: Reverse osmosis or Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Radium and uranium

Found: Radium (combined 226 + 228)

What removes it: Reverse osmosis.

See filters that remove it

More districts: Missouri water quality · All states · Something look wrong? Tell us