City of Bowie water quality

Updated 2026-10-22 · Maryland · Affiliate disclosure

We read 8 results from City of Bowie’s 2025 water quality report. No results over a legal limit; 1 above a health goal or guideline.

Serves about 25,000 people · Water system ID MD0160002 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Radium (combined 226 + 228)single sample · sampled 2023 · Bowie water plant · 2025 report, page 40.8 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Bariumsingle sample · Bowie water plant · 2025 report, page 40.02 ppm2 ppm2 ppmBelow the health goal
Chlorinehighest running annual average · range 0.92 to 1.18 · Distribution system · 2025 report, page 31.1 ppmNone set4 ppmBelow the legal limit
Copper90th percentile of 30 homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 40.02 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (TTHM)highest measured · range 3 to 7.6 · Distribution system · 2025 report, page 47.6 ppbNone set80 ppbBelow the legal limit
Fluorideas reported · sampled 2024 · Bowie water plant · 2025 report, page 40.43 ppm1 ppm4 ppmBelow the health goal
Lead90th percentile of 30 homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 4Not detected0.2 ppb15 ppb (action level)Not detected
Lithiumaverage · range 11.2 to 15.3 · sampled 2024 · Bowie water plant · 2025 report, page 413.3 ppbNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in City of Bowie’s water between Mar 2024 and Aug 2024. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium15.3 ppbFound in 2 of 2 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Radium and uranium

Found: Radium (combined 226 + 228)

What removes it: Reverse osmosis.

See filters that remove it

More districts: Maryland water quality · All states · Something look wrong? Tell us