Plainfield Water Works water quality

Updated 2026-10-22 · Indiana · Affiliate disclosure

We read 10 results from Plainfield Water Works’s 2025 water quality report. No results over a legal limit; 5 above a health goal or guideline.

Serves about 34,477 people · Water system ID IN5232020 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Copper90th percentile of homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 30.41 ppm0.3 ppm1.3 ppm (action level)Above the health goal1.4x the health goal
Fluoridehighest measured · range 0.52 to 1.65 · sampled 2023 · Treated water · 2025 report, page 31.65 ppm1 ppm4 ppmAbove the health goal1.7x the health goal
Gross alpha (radioactivity)highest measured · range 0.45 to 1.18 · sampled 2020 · Treated water · 2025 report, page 31.18 pCi/L0 pCi/L15 pCi/LAbove the health goalThe health goal is zero
Lead90th percentile of homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 31.69 ppb0.2 ppb15 ppb (action level)Above the health goal8.5x the health goal
Radium (combined 226 + 228)highest measured · range ND to 1.5 · sampled 2024 · Treated water · 2025 report, page 31.5 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Bariumhighest measured · range 0.28 to 0.56 · sampled 2023 · Treated water · 2025 report, page 30.56 ppm2 ppm2 ppmBelow the health goal
Chlorinehighest running annual average · range 1 to 2 · Distribution system · 2025 report, page 31 ppmNone set4 ppmBelow the legal limit
Disinfection byproducts (HAA5)highest running annual average · range 7.25 to 16 · Distribution system · 2025 report, page 316 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 22 to 53 · Distribution system · 2025 report, page 353 ppbNone set80 ppbBelow the legal limit
Nitrate (as N)highest measured · range ND to 2.11 · Treated water · 2025 report, page 32.11 ppm10 ppm10 ppmBelow the health goal

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Plainfield Water Works’s water between Mar 2025 and Oct 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • PFBS3.8 pptFound in 1 of 6 samples · highest resultNo federal limit in force for this one

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Lead

Found: Copper, Lead

What removes it: Reverse osmosis or Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Fluoride

Found: Fluoride

What removes it: Reverse osmosis.

See filters that remove itDo water filters remove fluoride?

Radium and uranium

Found: Gross alpha (radioactivity), Radium (combined 226 + 228)

What removes it: Reverse osmosis.

See filters that remove it

More districts: Indiana water quality · All states · Something look wrong? Tell us