North Aurora water quality

Updated 2026-10-23 · Illinois · Affiliate disclosure

We read 7 results from North Aurora’s 2024 water quality report. No results over a legal limit; 2 above a health goal or guideline.

Serves about 18,350 people · Water system ID IL0890600 · Read the district’s 2024 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2024 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Fluoridehighest measured · range 1.06 to 1.06 · 2024 report, page 61.06 ppm1 ppm4 ppmAbove the health goal1.1x the health goal
Radium (combined 226 + 228)highest measured · range 0.9 to 4.53 · 2024 report, page 64.53 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Bariumhighest measured · range 0.07 to 0.09 · 2024 report, page 60.09 ppm2 ppm2 ppmBelow the health goal
Chlorinehighest running annual average · range 0.1 to 0.1 · 2024 report, page 60.1 ppmNone set4 ppmBelow the legal limit
Copper90th percentile of 30 homes tested, 0 over the action level · Customer taps · 2024 report, page 60.15 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range ND to 2.11 · sampled 2019 · 2024 report, page 62 ppbNone set60 ppbBelow the legal limit
Lithiumsingle sample · 2024 report, page 632.6 ppbNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 1 number we weren’t sure about is held back until a person checks.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in North Aurora’s water between Aug 2024 and Feb 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium34.6 ppbFound in 4 of 4 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Fluoride

Found: Fluoride

What removes it: Reverse osmosis.

See filters that remove itDo water filters remove fluoride?

Radium and uranium

Found: Radium (combined 226 + 228)

What removes it: Reverse osmosis.

See filters that remove it

More districts: Illinois water quality · All states · Something look wrong? Tell us