Sjcu-Northwest Utilities Wtp water quality

Updated 2026-10-22 · Florida · Affiliate disclosure

We read 10 results from Sjcu-Northwest Utilities Wtp’s 2025 water quality report. No results over a legal limit; 3 above a health goal or guideline.

Serves about 48,040 people · Water system ID FL2554471 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Gross alpha (radioactivity)single sample · listed as a violation in the report · Wells · 2025 report, page 22 pCi/L0 pCi/L15 pCi/LAbove the health goalThe health goal is zero
Radium (combined 226 + 228)single sample · listed as a violation in the report · Wells · 2025 report, page 20.6 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Total dissolved solidshighest measured · range 520 to 566 · listed as a violation in the report · Wells · 2025 report, page 2566 ppm—500 ppm guidelineAbove the guideline1.1x the guideline (taste, odor or stains; not a health limit)
Bariumsingle sample · listed as a violation in the report · Wells · 2025 report, page 20.01 ppm2 ppm2 ppmBelow the health goal
Chlorinehighest running annual average · range 0.6 to 3.4 · listed as a violation in the report · Distribution system · 2025 report, page 33.4 ppmNone set4 ppmBelow the legal limit
Copper90th percentile of 93 homes tested, 0 over the action level · listed as a violation in the report · Customer taps · 2025 report, page 30.02 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range 9.23 to 16.4 · listed as a violation in the report · Distribution system · 2025 report, page 316.4 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 23.4 to 56 · listed as a violation in the report · Distribution system · 2025 report, page 356 ppbNone set80 ppbBelow the legal limit
Fluoridesingle sample · listed as a violation in the report · Wells · 2025 report, page 20.45 ppm1 ppm4 ppmBelow the health goal
Lead90th percentile of 93 homes tested, 0 over the action level · listed as a violation in the report · Customer taps · 2025 report, page 3Not detected0.2 ppb15 ppb (action level)Not detected

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 1 number we weren’t sure about is held back until a person checks.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Radium and uranium

Found: Gross alpha (radioactivity), Radium (combined 226 + 228)

What removes it: Reverse osmosis.

See filters that remove it

Salty taste / high TDS

Found: Total dissolved solids

What removes it: Reverse osmosis.

See filters that remove it

More districts: Florida water quality · All states · Something look wrong? Tell us