Orlando Utilities Commission water quality

Updated 2026-10-22 · Florida · Affiliate disclosure

We read 13 results from Orlando Utilities Commission’s 2025 water quality report. No results over a legal limit; 5 above a health goal or guideline.

Serves about 536,466 people · Water system ID FL3480962 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Bromatehighest running annual average · range ND to 10 · Water treatment plants · 2025 report, page 43.7 ppb0.1 ppb10 ppbAbove the health goal37x the health goal
Copper90th percentile of homes tested, 1 over the action level · sampled 2023 · Customer taps · 2025 report, page 50.5 ppm0.3 ppm1.3 ppm (action level)Above the health goal1.7x the health goal
Gross alpha (radioactivity)highest measured · range ND to 3.5 · sampled 2023 · Water treatment plants · 2025 report, page 43.5 pCi/L0 pCi/L15 pCi/LAbove the health goalThe health goal is zero
Lead90th percentile of homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 52 ppb0.2 ppb15 ppb (action level)Above the health goal10x the health goal
Radium (combined 226 + 228)highest measured · range ND to 1.5 · sampled 2023 · Water treatment plants · 2025 report, page 41.5 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Bariumhighest measured · range 0.01 to 0.04 · sampled 2023 · Water treatment plants · 2025 report, page 40.04 ppm2 ppm2 ppmBelow the health goal
Chlorinehighest running annual average · range 0.2 to 2.2 · Distribution system · 2025 report, page 41.2 ppmNone set4 ppmBelow the legal limit
Disinfection byproducts (HAA5)highest running annual average · range 6.64 to 38 · Distribution system · 2025 report, page 439.8 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 25.7 to 78.3 · Distribution system · 2025 report, page 472.2 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.56 to 0.89 · sampled 2023 · Water treatment plants · 2025 report, page 40.89 ppm1 ppm4 ppmBelow the health goal
Nitrate (as N)highest measured · range ND to 0.22 · Water treatment plants · 2025 report, page 40.22 ppm10 ppm10 ppmBelow the health goal
Nickelhighest measured · range ND to 2 · sampled 2023 · Water treatment plants · 2025 report, page 42 ppbNone setNoneNo health limit
Sodiumhighest measured · range 7.27 to 12.6 · sampled 2023 · Water treatment plants · 2025 report, page 412.6 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Disinfection byproducts

Found: Bromate

What removes it: Carbon block.

See filters that remove it

Lead

Found: Copper, Lead

What removes it: Reverse osmosis or Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Radium and uranium

Found: Gross alpha (radioactivity), Radium (combined 226 + 228)

What removes it: Reverse osmosis.

See filters that remove it

More districts: Florida water quality · All states · Something look wrong? Tell us