Ocud/Western Regional Wtr Sys (5 Wps) water quality

Updated 2026-10-22 · Florida · Affiliate disclosure

We read 10 results from Ocud/Western Regional Wtr Sys (5 Wps)’s 2025 water quality report. No results over a legal limit; 2 above a health goal or guideline.

Serves about 206,742 people · Water system ID FL3481546 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Lead90th percentile of homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 130.81 ppb0.2 ppb15 ppb (action level)Above the health goal4.1x the health goal
Radium (combined 226 + 228)highest measured · range ND to 1.6 · sampled 2023 · Treatment plants · 2025 report, page 131.6 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Bariumhighest measured · range 0.009 to 0.02 · sampled 2023 · Treatment plants · 2025 report, page 130.02 ppm2 ppm2 ppmBelow the health goal
Chlorinehighest running annual average · range 0.23 to 3.44 · Distribution system · 2025 report, page 131.8 ppmNone set4 ppmBelow the legal limit
Copper90th percentile of homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 130.16 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range 7.83 to 21.9 · Distribution system · 2025 report, page 1320.8 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 16.3 to 67.9 · Distribution system · 2025 report, page 1351.7 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range ND to 0.76 · sampled 2023 · Treatment plants · 2025 report, page 130.76 ppm1 ppm4 ppmBelow the health goal
Nitrate (as N)highest measured · range ND to 0.02 · Treatment plants · 2025 report, page 130.02 ppm10 ppm10 ppmBelow the health goal
Sodiumhighest measured · range 9.6 to 17 · sampled 2023 · Treatment plants · 2025 report, page 1317 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Ocud/Western Regional Wtr Sys (5 Wps)’s water between Apr 2024 and Nov 2024. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • PFOS5 pptFound in 3 of 10 samples · highest resultAbove the federal limit that takes effect in 2029 (4 ppt)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Radium and uranium

Found: Radium (combined 226 + 228)

What removes it: Reverse osmosis.

See filters that remove it

PFAS ("forever chemicals")

Found: PFOS (EPA testing)

What removes it: Reverse osmosis.

See filters that remove itWhat water filter removes PFAS?

More districts: Florida water quality · All states · Something look wrong? Tell us