Hcpud/Northwest Utilities water quality

Updated 2026-10-22 · Florida · Affiliate disclosure

We read 13 results from Hcpud/Northwest Utilities’s 2025 water quality report. No results over a legal limit; 4 above a health goal or guideline.

Serves about 206,485 people · Water system ID FL6290388 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Copper90th percentile of homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 130.76 ppm0.3 ppm1.3 ppm (action level)Above the health goal2.5x the health goal
Lead90th percentile of homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 130.75 ppb0.2 ppb15 ppb (action level)Above the health goal3.8x the health goal
Radium (combined 226 + 228)highest measured · range 0.78 to 0.95 · sampled 2020 · Treatment plants · 2025 report, page 120.95 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Tetrachloroethylene (PCE)highest running annual average · range ND to 1.1 · Treatment plants · 2025 report, page 120.28 ppb0.06 ppb5 ppbAbove the health goal4.7x the health goal
Bariumhighest measured · range 0.01 to 0.02 · Treatment plants · 2025 report, page 120.02 ppm2 ppm2 ppmBelow the health goal
Chloraminehighest running annual average · range 0.2 to 5.3 · Distribution system · 2025 report, page 123.2 ppmNone set4 ppmBelow the legal limit
Disinfection byproducts (HAA5)highest running annual average · range 8.4 to 31.7 · Distribution system · 2025 report, page 1233.1 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 11.9 to 41.8 · Distribution system · 2025 report, page 1245.7 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.6 to 0.72 · Treatment plants · 2025 report, page 120.72 ppm1 ppm4 ppmBelow the health goal
Mercuryhighest measured · range ND to 0.002 · Treatment plants · 2025 report, page 120.002 ppb1.2 ppb2 ppbBelow the health goal
Nitrate (as N)highest measured · range 0.04 to 0.17 · Treatment plants · 2025 report, page 120.17 ppm10 ppm10 ppmBelow the health goal
Turbidity (cloudiness)highest measured · Tampa Bay Water plant · 2025 report, page 130.17 NTUNone set1 NTUBelow the legal limit
Sodiumhighest measured · range 19 to 28 · Treatment plants · 2025 report, page 1228 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Lead

Found: Copper, Lead

What removes it: Reverse osmosis or Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Radium and uranium

Found: Radium (combined 226 + 228)

What removes it: Reverse osmosis.

See filters that remove it

Industrial chemicals and pesticides

Found: Tetrachloroethylene (PCE)

What removes it: Carbon block or RO.

See filters that remove it

More districts: Florida water quality · All states · Something look wrong? Tell us