City of Lakeland water quality

Updated 2026-10-22 · Florida · Affiliate disclosure

We read 12 results from City of Lakeland’s 2025 water quality report. No results over a legal limit; 2 above a health goal or guideline.

Serves about 193,297 people · Water system ID FL6531014 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Gross alpha (radioactivity)highest measured · range ND to 2.92 · sampled 2023 · Treatment plants · 2025 report, page 32.92 pCi/L0 pCi/L15 pCi/LAbove the health goalThe health goal is zero
Radium (combined 226 + 228)highest measured · range 1.39 to 1.41 · sampled 2023 · Treatment plants · 2025 report, page 31.41 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Bariumhighest measured · range 0.0038 to 0.005 · sampled 2023 · Treatment plants · 2025 report, page 30.005 ppm2 ppm2 ppmBelow the health goal
Chlorineaverage · range 1.81 to 2.27 · Distribution system · 2025 report, page 32 ppmNone set4 ppmBelow the legal limit
Copper90th percentile of homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 30.16 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range 4.3 to 22.8 · Distribution system · 2025 report, page 324 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 12.8 to 50.2 · Distribution system · 2025 report, page 343.3 ppbNone set80 ppbBelow the legal limit
Fluoridehighest measured · range 0.62 to 0.66 · sampled 2023 · Treatment plants · 2025 report, page 30.66 ppm1 ppm4 ppmBelow the health goal
Uraniumhighest measured · range ND to 0.19 · sampled 2023 · Treatment plants · 2025 report, page 30.19 ppb0.6 ppb30 ppbBelow the health goal
PFBA (a PFAS)highest measured · range ND to 2.1 · printed as 0.0021 ppb · sampled 2023 · Treatment plants (UCMR 5) · 2025 report, page 32.1 pptNone setNoneNo health limit
PFPeA (a PFAS)highest measured · range ND to 2.4 · printed as 0.0024 ppb · sampled 2023 · Treatment plants (UCMR 5) · 2025 report, page 32.4 pptNone setNoneNo health limit
Sodiumhighest measured · range 5.22 to 9.87 · sampled 2023 · Treatment plants · 2025 report, page 39.87 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 1 number we weren’t sure about is held back until a person checks.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Radium and uranium

Found: Gross alpha (radioactivity), Radium (combined 226 + 228)

What removes it: Reverse osmosis.

See filters that remove it

More districts: Florida water quality · All states · Something look wrong? Tell us