We read 13 results from Camden Pump District’s 2025 water quality report. No results over a legal limit; 2 above a health goal or guideline.
Serves about 17,208 people · Water system ID DE0000124 · Read the district’s 2025 report (opens in a new tab)
Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.
Results from the 2025 report
Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.
| Contaminant | Result | Health goal | Legal limit | What it means |
|---|---|---|---|---|
| Arsenichighest measured · range 3 to 3 · 2025 report, page 2 | 3 ppb | 0.004 ppb | 10 ppb | Above the health goal750x the health goal |
| Lead90th percentile of homes tested, 0 over the action level · sampled 2023 · 2025 report, page 2 | 2 ppb | 0.2 ppb | 15 ppb (action level) | Above the health goal10x the health goal |
| Chlorideaverage · range 3 to 7 · 2025 report, page 2 | 6 ppm | — | 250 ppm guideline | Within the guideline |
| Chlorinehighest measured · range 0.4 to 1.7 · 2025 report, page 2 | 1.7 ppm | None set | 4 ppm | Below the legal limit |
| Copper90th percentile of homes tested, 0 over the action level · sampled 2023 · 2025 report, page 2 | 0.1 ppm | 0.3 ppm | 1.3 ppm (action level) | Below the health goal |
| Disinfection byproducts (HAA5)highest measured · range 4 to 4 · 2025 report, page 2 | 4 ppb | None set | 60 ppb | Below the legal limit |
| Disinfection byproducts (TTHM)highest measured · range 12 to 12 · 2025 report, page 2 | 12 ppb | None set | 80 ppb | Below the legal limit |
| Fluoridehighest measured · range 0.9 to 0.9 · 2025 report, page 2 | 0.9 ppm | 1 ppm | 4 ppm | Below the health goal |
| Ironaverage · range 0.1 to 0.2 · 2025 report, page 2 | 0.1 ppm | — | 0.3 ppm guideline | Within the guideline |
| Sulfateaverage · range 2 to 4 · 2025 report, page 2 | 3 ppm | — | 250 ppm guideline | Within the guideline |
| Alkalinityaverage · range 118 to 285 · 2025 report, page 2 | 181 ppm | None set | None | No health limit |
| Lithiumaverage · range 17 to 22 · 2025 report, page 2 | 20 ppb | None set | None | No health limit |
| Sodiumaverage · range 10 to 133 · 2025 report, page 2 | 55 ppm | None set | None | No health limit |
Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.
EPA testing for PFAS and lithium
EPA’s own nationwide testing (UCMR 5) found these in Camden Pump District’s water between Jan 2025 and Jul 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.
- Lithium17.4 ppbFound in 9 of 10 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)
Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.
What you can do
Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.
Lead
Found: Lead
What removes it: Certified carbon block or RO.