Metropolitan District Commission water quality

Updated 2026-10-22 · Connecticut · Affiliate disclosure

We read 13 results from Metropolitan District Commission’s 2025 water quality report. No results over a legal limit; 1 above a health goal or guideline.

Serves about 390,887 people · Water system ID CT0640011 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Lead90th percentile of 65 homes tested, 3 over the action level · sampled 2023 · Customer taps · 2025 report, page 87 ppb0.2 ppb15 ppb (action level)Above the health goal35x the health goal
Bariumaverage · range 0.006 to 0.007 · System · 2025 report, page 80.006 ppm2 ppm2 ppmBelow the health goal
Chlorideaverage · range 8.77 to 11.2 · System · 2025 report, page 810.1 ppm—250 ppm guidelineWithin the guideline
Chlorineaverage · range 0.01 to 1.04 · Distribution system · 2025 report, page 80.5 ppmNone set4 ppmBelow the legal limit
Copper90th percentile of 65 homes tested, 0 over the action level · sampled 2023 · Customer taps · 2025 report, page 80.16 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range 4.25 to 53.3 · Distribution system · 2025 report, page 841.4 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 7.76 to 72.3 · Distribution system · 2025 report, page 856.8 ppbNone set80 ppbBelow the legal limit
Fluorideaverage · range 0.6 to 0.86 · System · 2025 report, page 80.7 ppm1 ppm4 ppmBelow the health goal
Nitrate (as N)average · range ND to 0.05 · System · 2025 report, page 80.04 ppm10 ppm10 ppmBelow the health goal
pHaverage · range 7.13 to 7.99 · System · 2025 report, page 87.41——Normal range
Sulfateaverage · range 3.6 to 7.9 · System · 2025 report, page 85.1 ppm—250 ppm guidelineWithin the guideline
Turbidity (cloudiness)average · range 0.04 to 0.47 · West Hartford plant, highest of 2 sources · 2025 report, page 80.08 NTUNone set1 NTUBelow the legal limit
Sodiumaverage · range 7.7 to 17.8 · System · 2025 report, page 810.9 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

More districts: Connecticut water quality · All states · Something look wrong? Tell us