Woodmoor Wsd water quality

Updated 2026-10-23 · Colorado · Affiliate disclosure

We read 11 results from Woodmoor Wsd’s 2024 water quality report. No results over a legal limit; 3 above a health goal or guideline.

Serves about 17,694 people · Water system ID CO0121950 · Read the district’s 2024 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2024 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Fluorideaverage · range 0.65 to 1.48 · sampled 2022 · 2024 report, page 51.18 ppm1 ppm4 ppmAbove the health goal1.2x the health goal
Lead90th percentile of 30 homes tested, 0 over the action level · sampled 2023 · 2024 report, page 31 ppb0.2 ppb15 ppb (action level)Above the health goal5x the health goal
Radium (combined 226 + 228)average · range 1.1 to 1.1 · sampled 2023 · 2024 report, page 41.1 pCi/L0 pCi/L5 pCi/LAbove the health goalThe health goal is zero
Bariumaverage · range 0.06 to 0.06 · sampled 2023 · 2024 report, page 40.06 ppm2 ppm2 ppmBelow the health goal
Chromium (total)average · range 1 to 1 · sampled 2023 · 2024 report, page 51 ppbNone set100 ppbBelow the legal limit
Copper90th percentile of 30 homes tested, 0 over the action level · sampled 2023 · 2024 report, page 30.12 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)average · range ND to 23.1 · sampled 2023 · 2024 report, page 42.94 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)average · range ND to 109 · sampled 2023 · 2024 report, page 410.8 ppbNone set80 ppbBelow the legal limit
Nitrate (as N)average · range ND to 0.3 · sampled 2023 · 2024 report, page 50.06 ppm10 ppm10 ppmBelow the health goal
Seleniumaverage · range 1 to 1 · sampled 2023 · 2024 report, page 51 ppb30 ppb50 ppbBelow the health goal
Sodiumaverage · range 18.6 to 18.6 · sampled 2023 · 2024 report, page 518.6 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Woodmoor Wsd’s water between Feb 2024 and May 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • PFBS3.3 pptFound in 1 of 14 samples · highest resultNo federal limit in force for this one
  • Lithium31.8 ppbFound in 14 of 14 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Fluoride

Found: Fluoride

What removes it: Reverse osmosis.

See filters that remove itDo water filters remove fluoride?

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Radium and uranium

Found: Radium (combined 226 + 228)

What removes it: Reverse osmosis.

See filters that remove it