Denver Water Board water quality

Updated 2026-10-22 · Colorado · Affiliate disclosure

We read 24 results from Denver Water Board’s 2025 water quality report. No results over a legal limit; 2 above a health goal or guideline.

Serves about 1,287,000 people · Water system ID CO0116001 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Lead90th percentile of 337 homes tested, 1 over the action level · Customer taps, Jan-Jun 2025 (337 samples), highest of 2 sources · 2025 report, page 134 ppb0.2 ppb15 ppb (action level)Above the health goal20x the health goal
Total coliform bacteriahighest month · Distribution system · 2025 report, page 130.5 % positive0 % positive5 % positiveAbove the health goalThe health goal is zero
Aluminumaverage · range 0.02 to 0.09 · printed as 31.4 ppb · Distribution system · 2025 report, page 140.03 ppm—0.2 ppm guidelineWithin the guideline
Bariumaverage · range 0.04 to 0.04 · printed as 40.1 ppb · Marston plant, highest of 3 sources · 2025 report, page 110.04 ppm2 ppm2 ppmBelow the health goal
Chlorideaverage · range 6.8 to 35 · printed as 24,000 ppb · Distribution system · 2025 report, page 1424 ppm—250 ppm guidelineWithin the guideline
Chromium (total)average · range ND to 1.8 · Foothills plant, highest of 3 sources · 2025 report, page 100.5 ppbNone set100 ppbBelow the legal limit
Copper90th percentile of 337 homes tested, 0 over the action level · printed as 60 ppb · Customer taps, Jan-Jun 2025 (337 samples), highest of 2 sources · 2025 report, page 130.06 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range 7.2 to 26.7 · Distribution system · 2025 report, page 1319.5 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 8.8 to 41.1 · Distribution system · 2025 report, page 1335.5 ppbNone set80 ppbBelow the legal limit
Fluorideaverage · range 0.53 to 0.75 · printed as 619 ppb · Marston plant, highest of 3 sources · 2025 report, page 110.62 ppm1 ppm4 ppmBelow the health goal
Manganeseaverage · range ND to 0.03 · printed as 1.9 ppb · Distribution system · 2025 report, page 140.0019 ppm—0.05 ppm guidelineWithin the guideline
Mercuryaverage · range ND to 0.12 · Foothills plant · 2025 report, page 10Not detected1.2 ppb2 ppbNot detected
Nitrate (as N)average · range ND to 0.18 · printed as 104 ppb · Foothills plant, highest of 3 sources · 2025 report, page 100.1 ppm10 ppm10 ppmBelow the health goal
PFOA (a PFAS)average · printed as BRL ppb · Entry points, all plants (UCMR 5) · 2025 report, page 15Not detected0.007 ppt4 ppt from 2029Not detected
PFOS (a PFAS)average · printed as BRL ppb · Entry points, all plants (UCMR 5) · 2025 report, page 15Not detected1 ppt4 ppt from 2029Not detected
Sulfateaverage · range 23 to 83 · printed as 58,300 ppb · Distribution system · 2025 report, page 1458.3 ppm—250 ppm guidelineWithin the guideline
Turbidity (cloudiness)highest measured · Northwater plant, highest of 3 sources · 2025 report, page 120.17 NTUNone set1 NTUBelow the legal limit
Zincaverage · range ND to 0.01 · printed as 2.8 ppb · Distribution system · 2025 report, page 140.0028 ppm—5 ppm guidelineWithin the guideline
Alkalinityaverage · range 41 to 82 · printed as 65,037 ppb · Distribution system · 2025 report, page 1465 ppmNone setNoneNo health limit
Conductivityaverage · range 150 to 420 · Distribution system · 2025 report, page 14338 µS/cmNone setNoneNo health limit
Hardnessaverage · range 3.22 to 7.25 · Distribution system · 2025 report, page 146.14 gpg (105 ppm)——Moderately hard
Lithiumaverage · range 9 to 9.4 · sampled 2023 · Marston plant, highest of 2 sources · 2025 report, page 159.23 ppbNone setNoneNo health limit
Nickelaverage · range ND to 1.6 · Foothills plant, highest of 2 sources · 2025 report, page 101 ppbNone setNoneNo health limit
Sodiumaverage · range 19.1 to 27.2 · printed as 23,820 ppb · Marston plant, highest of 3 sources · 2025 report, page 1123.8 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Denver Water Board’s water between Mar 2023 and Apr 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium10.8 ppbFound in 5 of 15 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Bacteria and viruses

Found: Total coliform bacteria

What removes it: UV purification (and tell your utility).

See filters that remove itDo I need a UV water purifier?

More districts: Colorado water quality · All states · Something look wrong? Tell us