We read 12 results from Colorado Springs Utilities’s 2025 water quality report. No results over a legal limit; 1 above a health goal or guideline.

Serves about 464,111 people · Water system ID CO0121150 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Lead90th percentile of 59 homes tested, 2 over the action level · sampled 2024 · Customer taps · 2025 report, page 185.7 ppb0.2 ppb15 ppb (action level)Above the health goal29x the health goal
Bariumaverage · range 0.02 to 0.05 · Treatment plants · 2025 report, page 150.03 ppm2 ppm2 ppmBelow the health goal
Copper90th percentile of 59 homes tested, 0 over the action level · sampled 2024 · Customer taps · 2025 report, page 180.12 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)average · range 11.4 to 42.4 · Distribution sites · 2025 report, page 1723.4 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)average · range 25.4 to 62.4 · Distribution sites · 2025 report, page 1740.9 ppbNone set80 ppbBelow the legal limit
Fluorideaverage · range 0.15 to 1.23 · Treatment plants · 2025 report, page 150.48 ppm1 ppm4 ppmBelow the health goal
Nitrate (as N)average · range ND to 0.4 · Treatment plants · 2025 report, page 150.14 ppm10 ppm10 ppmBelow the health goal
Seleniumaverage · range ND to 5 · Treatment plants · 2025 report, page 151.5 ppb30 ppb50 ppbBelow the health goal
Turbidity (cloudiness)highest measured · Treatment plants · 2025 report, page 160.51 NTUNone set1 NTUBelow the legal limit
Xylenesaverage · range ND to 0.0012 · printed as 0.44 ppb · Treatment plants · 2025 report, page 150.00044 ppm10 ppm10 ppmBelow the health goal
Lithiumaverage · range ND to 14.8 · Treatment plants (UCMR) · 2025 report, page 186.12 ppbNone setNoneNo health limit
Sodiumaverage · range 8.4 to 23.3 · Treatment plants · 2025 report, page 1512.6 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 1 number we weren’t sure about is held back until a person checks.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Colorado Springs Utilities’s water between Oct 2024 and Jul 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium17 ppbFound in 11 of 24 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Lead

Found: Lead

What removes it: Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

More districts: Colorado water quality · All states · Something look wrong? Tell us