Soquel Creek Water District water quality

Updated 2026-10-22 · California · Affiliate disclosure

We read 14 results from Soquel Creek Water District’s 2024 water quality report. No results over a legal limit; 1 above a health goal or guideline.

Serves about 40,809 people · Water system ID CA4410017 · Read the district’s 2024 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2024 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Arsenicaverage · range ND to 2.8 · Wells · 2024 report, page 110.5 ppb0.004 ppb10 ppbAbove the health goal125x the health goal
Chlorideaverage · range 18 to 59 · Wells · 2024 report, page 1130 ppm—250 ppm guidelineWithin the guideline
Chlorinehighest running annual average · range 0.21 to 1.52 · Distribution system · 2024 report, page 110.78 ppmNone set4 ppmBelow the legal limit
Chromium (total)average · range ND to 14 · Wells · 2024 report, page 116.6 ppbNone set100 ppbBelow the legal limit
Copper90th percentile of 30 homes tested, 0 over the action level · sampled 2022 · Customer taps · 2024 report, page 120.26 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)highest running annual average · range ND to 10 · Distribution system · 2024 report, page 119 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 5 to 50 · Distribution system · 2024 report, page 1142 ppbNone set80 ppbBelow the legal limit
Fluorideaverage · range ND to 0.1 · Wells · 2024 report, page 110.08 ppm1 ppm2 ppmBelow the health goal
Lead90th percentile of 30 homes tested, 1 over the action level · sampled 2022 · Customer taps · 2024 report, page 12Not detected0.2 ppb15 ppb (action level)Not detected
Nitrate (as N)average · range ND to 3.4 · Wells · 2024 report, page 110.4 ppm10 ppm10 ppmBelow the health goal
Sulfateaverage · range 17 to 62 · Wells · 2024 report, page 1137 ppm—250 ppm guidelineWithin the guideline
Total dissolved solidsaverage · range 206 to 358 · Wells · 2024 report, page 11274 ppm—500 ppm guidelineWithin the guideline
Hardnessaverage · range 4.74 to 12 · Wells · 2024 report, page 119.41 gpg (161 ppm)——Hard
Sodiumaverage · range 16 to 86 · Wells · 2024 report, page 1139 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Soquel Creek Water District’s water between May 2025 and Jun 2026. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium89.8 ppbFound in 27 of 28 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Arsenic

Found: Arsenic

What removes it: Reverse osmosis.

See filters that remove it

More districts: California water quality · All states · Something look wrong? Tell us