Rainbow Municipal WD water quality

Updated 2026-10-22 · California · Affiliate disclosure

We read 17 results from Rainbow Municipal WD’s 2025 water quality report. No results over a legal limit; 2 above a health goal or guideline.

Serves about 23,536 people · Water system ID CA3710016 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Total dissolved solidsaverage · range 501 to 513 · MWD Skinner Water Treatment Plant (supplier) · 2025 report, page 11507 ppm—500 ppm guidelineAbove the guideline1x the guideline (taste, odor or stains; not a health limit)
Uraniumaverage · range ND to 4.47 · printed as 2 pCi/L · MWD Skinner Water Treatment Plant (supplier) · 2025 report, page 112.98 ppb0.6 ppb30 ppbAbove the health goal5x the health goal
Aluminumaverage · range ND to 0.12 · printed as 57 ppb · MWD Skinner Water Treatment Plant (supplier) · 2025 report, page 100.06 ppm—0.2 ppm guidelineWithin the guideline
Chloramineaverage · range 1.48 to 2.44 · Distribution system · 2025 report, page 112 ppmNone set4 ppmBelow the legal limit
Chlorideaverage · range 87 to 91 · MWD Skinner Water Treatment Plant (supplier) · 2025 report, page 1189 ppm—250 ppm guidelineWithin the guideline
Coloraverage · range 1 to 2 · MWD Skinner Water Treatment Plant (supplier) · 2025 report, page 112 CU—15 CU guidelineWithin the guideline
Copper90th percentile of 30 homes tested, 0 over the action level · sampled 2024 · Customer taps · 2025 report, page 100.24 ppm0.3 ppm1.3 ppm (action level)Below the health goal
Disinfection byproducts (HAA5)average · range 3 to 18 · Distribution system · 2025 report, page 1110 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)average · range 17 to 58 · Distribution system · 2025 report, page 1133 ppbNone set80 ppbBelow the legal limit
Fluorideaverage · range 0.6 to 0.8 · MWD Skinner Water Treatment Plant (supplier) · 2025 report, page 100.7 ppm1 ppm2 ppmBelow the health goal
Sulfateaverage · range 164 to 171 · MWD Skinner Water Treatment Plant (supplier) · 2025 report, page 11168 ppm—250 ppm guidelineWithin the guideline
Turbidity (cloudiness)highest measured · MWD Skinner Water Treatment Plant (supplier) · 2025 report, page 100.07 NTUNone set1 NTUBelow the legal limit
Boronaverage · printed as 130 ppb · MWD Skinner Water Treatment Plant (supplier) · 2025 report, page 110.13 ppmNone setNoneNo health limit
Conductivityaverage · range 824 to 847 · MWD Skinner Water Treatment Plant (supplier) · 2025 report, page 11836 µS/cmNone setNoneNo health limit
Hardnessaverage · range 13.3 to 13.6 · MWD Skinner Water Treatment Plant (supplier) · 2025 report, page 1113.5 gpg (230 ppm)——Very hard
Lithiumaverage · range 26 to 30 · Rainbow MWD · 2025 report, page 1128 ppbNone setNoneNo health limit
Sodiumaverage · range 83 to 87 · MWD Skinner Water Treatment Plant (supplier) · 2025 report, page 1185 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 1 number we weren’t sure about is held back until a person checks.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Rainbow Municipal WD’s water between May 2024 and Feb 2025. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium44 ppbFound in 4 of 4 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Salty taste / high TDS

Found: Total dissolved solids

What removes it: Reverse osmosis.

See filters that remove it

Radium and uranium

Found: Uranium

What removes it: Reverse osmosis.

See filters that remove it

More districts: California water quality · All states · Something look wrong? Tell us