Oxnard Water Dept water quality

Updated 2026-10-22 · California · Affiliate disclosure

We read 25 results from Oxnard Water Dept’s 2025 water quality report. No results over a legal limit; 8 above a health goal or guideline.

Serves about 200,232 people · Water system ID CA5610007 · Read the district’s 2025 report (opens in a new tab)

Open this district in the water lookupCompare with your own test results, see the district map and get matched filters.

Results from the 2025 report

Each number is copied from the district’s report and links to the page it’s printed on. Where the report lists several plants, wells or purchased water, the highest is shown.

ContaminantResultHealth goalLegal limitWhat it means
Arsenichighest measured · range 0.63 to 0.74 · Blended system · 2025 report, page 80.74 ppb0.004 ppb10 ppbAbove the health goal185x the health goal
Copper90th percentile of 50 homes tested, 1 over the action level · printed as 790 ppb · sampled 2024 · Customer taps (50 sites) · 2025 report, page 90.79 ppm0.3 ppm1.3 ppm (action level)Above the health goal2.6x the health goal
Gross alpha (radioactivity)average · range 1.58 to 3.71 · Blended system · 2025 report, page 92.79 pCi/L0 pCi/L15 pCi/LAbove the health goalThe health goal is zero
Gross beta (radioactivity)average · range 3.9 to 5.76 · Blended system · 2025 report, page 94.89 pCi/L0 pCi/L50 pCi/LAbove the health goalThe health goal is zero
Lead90th percentile of 50 homes tested, 3 over the action level · sampled 2024 · Customer taps (50 sites) · 2025 report, page 95.5 ppb0.2 ppb15 ppb (action level)Above the health goal28x the health goal
Sulfateaverage · range 64 to 600 · Blended system · 2025 report, page 8338 ppm—250 ppm guidelineAbove the guideline1.4x the guideline (taste, odor or stains; not a health limit)
Total dissolved solidsaverage · range 260 to 1,000 · Blended system · 2025 report, page 8782 ppm—500 ppm guidelineAbove the guideline1.6x the guideline (taste, odor or stains; not a health limit)
Uraniumaverage · range 5.36 to 6.71 · printed as 4.15 pCi/L · Blended system · 2025 report, page 96.18 ppb0.6 ppb30 ppbAbove the health goal10x the health goal
Chlorideaverage · range 51 to 67 · Blended system · 2025 report, page 856 ppm—250 ppm guidelineWithin the guideline
Chlorineaverage · range 0.06 to 3 · Distribution system · 2025 report, page 91.51 ppmNone set4 ppmBelow the legal limit
Disinfection byproducts (HAA5)highest running annual average · range 1.6 to 7.3 · Distribution system · 2025 report, page 93.7 ppbNone set60 ppbBelow the legal limit
Disinfection byproducts (TTHM)highest running annual average · range 9.5 to 36 · Distribution system · 2025 report, page 922.2 ppbNone set80 ppbBelow the legal limit
Ironaverage · range ND to 0.44 · Blended system · 2025 report, page 80.09 ppm—0.3 ppm guidelineWithin the guideline
Nitrate (as N)average · range 0.44 to 7 · Blended system · 2025 report, page 81.88 ppm10 ppm10 ppmBelow the health goal
PFHxS (a PFAS)average · range 0.43 to 0.86 · Blended system (UCMR 5) · 2025 report, page 90.69 pptNone set10 ppt from 2029Below the legal limit
pHaverage · range 6.24 to 8.2 · Blended system · 2025 report, page 87.5——Normal range
Seleniumaverage · range 3.6 to 4.44 · Blended system · 2025 report, page 83.98 ppb30 ppb50 ppbBelow the health goal
Total coliform bacteriahighest month · Distribution system · 2025 report, page 8Not detected0 % positive5 % positiveNot detected
Turbidity (cloudiness)highest measured · Calleguas MWD Lake Bard plant · 2025 report, page 80.16 NTUNone set1 NTUBelow the legal limit
Alkalinityaverage · range 110 to 300 · Blended system · 2025 report, page 8183 ppmNone setNoneNo health limit
Boronaverage · range 0.53 to 0.55 · printed as 535 ppb · Source water before blending · 2025 report, page 80.54 ppmNone setNoneNo health limit
Calciumaverage · range 30.5 to 233 · Blended system · 2025 report, page 8104 ppmNone setNoneNo health limit
Hardnessaverage · range 7.66 to 54.4 · Blended system · 2025 report, page 824.5 gpg (419 ppm)——Very hard
Magnesiumaverage · range 13.2 to 84.3 · Blended system · 2025 report, page 837.3 ppmNone setNoneNo health limit
Sodiumaverage · range 77 to 87 · Blended system · 2025 report, page 881 ppmNone setNoneNo health limit

Utility results describe the whole system, measured where water enters the pipes, not your tap. Your home’s plumbing can add lead or copper. 1 number we weren’t sure about is held back until a person checks.

EPA testing for PFAS and lithium

EPA’s own nationwide testing (UCMR 5) found these in Oxnard Water Dept’s water between Mar 2023 and Dec 2023. These are EPA lab results, separate from the district’s report. Anything not listed was not detected.

  • Lithium39 ppbFound in 12 of 12 samples · highest resultAbove EPA’s health reference level of 10 ppb (a guide, not a legal limit)

Source: EPA UCMR 5 occurrence data. The highest single result is shown; one high sample doesn’t mean every glass is that high.

What you can do

Nothing here is an emergency notice: if the district has a violation, it must tell customers directly. If you’d like to lower these at your tap, these are the treatments that remove them, and the catalog shows the models certified for each. Ranking is by certified removal; commissions never change the order.

Arsenic

Found: Arsenic

What removes it: Reverse osmosis.

See filters that remove it

Lead

Found: Copper, Lead

What removes it: Reverse osmosis or Certified carbon block or RO.

See filters that remove itWhat water filter removes lead?

Radium and uranium

Found: Gross alpha (radioactivity), Gross beta (radioactivity), Uranium

What removes it: Reverse osmosis.

See filters that remove it

Salty taste / high TDS

Found: Sulfate, Total dissolved solids

What removes it: Reverse osmosis.

See filters that remove it

More districts: California water quality · All states · Something look wrong? Tell us